Key result
Transfemoral SAPIEN XT TAVI yields a ~12% 30-day VARC-2 composite safety event rate in intermediate-risk patients.
Why the study?
Few studies have examined the safety and efficacy of transcatheter aortic valve implantation for severe aortic stenosis in Australian patients at intermediate surgical risk.
Observational (n=199)
Open-label
Yes
Answers are grounded in this paper and cite their sources.
Provides Australian real-world TAVI data in intermediate-risk AS; leaves open generalizability beyond this single-arm cohort.
Background: Few studies have examined the safety and efficacy of transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS) in Australian patients. SOLACE-AU was a single-arm, open-label clinical trial conducted in Australian hospitals to determine the safety, performance, and cost implications of TAVI in patients with severe, symptomatic AS at intermediate surgical risk.Methods: This was a prospective, pragmatic, single-arm, multi-center, observational trial of 199 patients with severe, symptomatic AS treated with transfemoral TAVI using the SAPIEN XT transcatheter heart valve (THV) at 11 hospitals in Australia. The primary outcome was Valve Academic Research Consortium-2 (VARC-2) criteria – a composite of seven safety endpoints. Kaplan–Meier (KM) estimates and descriptive analyses were used to evaluate the impact of transfemoral TAVI on safety and valve performance. We also evaluated patient health-related quality of life (QoL) and healthcare resources used throughout the trial.Results: The valve was successfully implanted in 88% of patients. The VARC-2 outcome at 30 days was 12.1% (95% CI: 8.3–17.5%), and almost 90% of patients had improved heart failure symptoms at 1 year based on New York Heart Association functional class criteria. Patient QoL remained stable over time, with mean EQ-5D-3L scores being 0.71 ± 0.20 at baseline and 0.71 ± 0.21 at 2 years. Duration of post-procedure hospitalization (mean: 6.9 ± 4.7 days) decreased as procedural familiarity increased. The median total cost of TAVI decreased 10.1% at 3 years after introduction of the procedure at the sites.Conclusions: The SOLACE-AU trial demonstrated favorable safety and performance of the SAPIEN XT valve in patients with AS at intermediate risk of surgical complications.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2019) conducted an observational in Severe, symptomatic aortic stenosis (n=199). Transfemoral transcatheter aortic valve implantation (TAVI) using the SAPIEN XT valve was evaluated on Valve Academic Research Consortium-2 (VARC-2) criteria - a composite of seven safety endpoints at 30 days (95% CI 8.3-17.5). Transfemoral TAVI using the SAPIEN XT valve in intermediate-risk patients had a 30-day VARC-2 composite safety outcome rate of 12.1%.
Synapse has enriched 10 related papers. Consider them for comparative context: