Key result
Longer bipolar local activation time linked to ~7% higher odds of successful LV summit ablation.
Why the study?
Visual inspection of unipolar electrogram QS morphology is subjective and has poor specificity for predicting successful ablation sites in idiopathic outflow tract ventricular arrhythmia mapping and ablation.
Cohort (n=78)
No
Odds Ratio: 1.07 (95% CI 1.02–1.11)
p-value: p=0.003
Longer bipolar LAT may guide target selection in LV summit VA ablation; leaves open prospective validation before practice change.
INTRODUCTION: Radiofrequency catheter ablation is an effective therapy for focal idiopathic outflow tract ventricular arrhythmia (OTVA). However, visual inspection of the unipolar electrogram (EGM) QS morphology is subjective with a poor specificity for predicting successful ablation sites. This study aims to evaluate the predictive value of unipolar and bipolar EGMs in OTVA mapping and ablation. METHODS AND RESULTS: Twenty-two patients scheduled for idiopathic OTVA ablation were prospectively enrolled. During the procedure, unipolar and bipolar EGMs were recorded simultaneously and visually inspected by the operator to identify their values for predicting arrhythmogenic sites. Quantitative features of the unipolar EGM including the ratio of amplitude of the first positive peak versus the nadir (R-ratio), the maximum descending slope (MaxSlope), and the time interval between the initial deflection point to the MaxSlope (D-Max) were calculated for each target site in offline analysis. EGMs from 100 sites were collected in 20 patients and analyzed. The bipolar reverse polarity characteristic was not as practical for identifying successful ablation site as the unipolar QS characteristic. Successful ablation sites demonstrated smaller R-ratio and shorter D-Max than unsuccessful sites, but no significant difference in MaxSlope. A unipolar EGM-derived quantitative criterion provided significantly better specificity (0.70) than visual inspection (0.37) without compromising on the sensitivity (0.83 vs. 0.89). CONCLUSION: The bipolar reverse polarity characteristic was not a practical method for identifying target in idiopathic OTVA ablation. The unipolar EGM-derived quantitative criteria have better predictive performance than visual inspection of the QS characteristic and are likely to reduce unnecessary ablation sites.
No takes yet. Share an insight, caveat, or question.
Niu et al. (2018) conducted a cohort in Idiopathic ventricular arrhythmias originating near the left ventricular summit (n=78). Longer bipolar local activation time (LAT Bi) vs. Shorter bipolar local activation time was evaluated on Successful ablation of ventricular arrhythmias (OR 1.07, 95% CI 1.02-1.11, p=0.003). Longer bipolar local activation time (LAT Bi) was the only independent predictor of successful ablation targets in patients with left ventricular summit ventricular arrhythmias (OR 1.07, p=0.003).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: