Answers are grounded in this paper and cite their sources.
The effect of building orientation on the very-high-cycle fatigue (VHCF) response of Ti-6Al-4V specimens produced through selective laser melting (SLM) process with three different building orientations (0°, 45° and 90°) has been experimentally assessed. The fatigue performance decreases with different building orientations from 0° to 90°. The fatigue crack origin has been found to be always an internal defect both at high-cycle fatigue and VHCF regime independent of building orientations. Size of defects induced fatigue failures and the stress intensity factor range decrease with the number of cycles to failure. By considering the VHCF strength at 10 9 cycles, the median value decreases from 217 MPa (0°) to 201 MPa (45°) and finally to 155 MPa (90°), with a 40% reduction from 0° to 90°. The building orientation significantly influences both the defect size and the resulting VHCF response.
No takes yet. Share an insight, caveat, or question.
Qian et al. (2020) studied this question.