Key result
Cardiac implantable electronic device status did not significantly increase procedural mortality after transcatheter tricuspid valve intervention (RR 1.17; 95% CI 0.48-2.86).
Why the study?
Up to a third of patients undergoing transcatheter tricuspid valve interventions (TTVI) have a cardiac implantable electronic device (CIED), which may increase TR and TTVI complication risks, yet no meta-analyses had assessed the influence of CIEDs on TTVI outcomes.
Does the presence of a cardiac implantable electronic device affect in-hospital procedural mortality and clinical outcomes in patients undergoing transcatheter tricuspid valve interventions?
Meta-Analysis (n=6,664)
Does the presence of a cardiac implantable electronic device affect in-hospital procedural mortality and clinical outcomes in patients undergoing transcatheter tricuspid valve interventions?
In patients undergoing transcatheter tricuspid valve interventions, having a cardiac implantable electronic device does not increase mortality or major adverse events, but is associated with a higher risk of severe or worse residual tricuspid regurgitation.
Background Severe tricuspid regurgitation (TR) is associated with significant morbidity and mortality. Transcatheter tricuspid valve interventions (TTVI) are commonly employed in severe tricuspid valvulopathy in patients with high surgical risk. Up to a third of patients undergoing TTVI will also have a cardiac implantable electronic device (CIED), which may increase the risk of both developing TR and the complications of TTVI. However, there have been no meta-analyses conducted assessing the influence of CIEDs on TTVI outcomes. Purpose To compare the clinical safety and efficacy of TTVI in patients with CIED versus without CIEDs. Methods PubMed, Cochrane CENTRAL, and Embase were systematically searched for randomised and non-randomised studies on the topic. Studies reporting data on TTVI outcomes stratified by CIED status were included. A systematic review and meta-analysis was conducted, using the Mantel-Haenszel method and a random-effects model, reporting risk ratios (RR) and 95% confidence intervals (CI) for all dichotomous outcomes. The primary outcome was in-hospital procedural mortality. Results 10 studies (n=6,664) were included in the systematic review, with data from 7 studies (n=5,427) included in the meta-analysis, with a focus on in-hospital and 30 day follow-up data. 3 studies were not included in the meta-analysis due to a lack of compatible data. Procedural mortality was not significantly different (RR 1.17; 95% CI 0.48-2.86). Residual TR moderate or worse (RR 1.12; 95% CI 0.97-1.30), successful device implantation (RR 1.00; 95% CI 0.95-1.06), major bleeding (RR 0.81; 95% CI 0.51-1.29), re-intervention (RR 1.20; 95% CI 0.67-2.13), stroke (RR 0.76; 95% CI 0.16-3.61), heart failure hospitalization (RR 1.03; 95% CI 0.71-1.48), patients ≤NYHA Class 2 (RR 1.00; 95% CI 0.91-1.09), and 1-year all-cause mortality (RR 1.23; 95% CI 0.86-1.74) were not significantly different. Residual TR severe or worse was more frequent in the CIED group (RR 1.38; 95% CI 1.03-1.84). Conclusion CIED status is not associated with a significantly higher early or late mortality, reduced procedural success, or major adverse events after TTVI. The increased risk of severe or worse residual TR suggests possible decreased efficacy of TR attenuation in patients with CIED.Successful Dev. Implant. and Severe+ TR at FUFor image description, please refer to the figure legend and surrounding text.Proc. Mortality and Maj.
No takes yet. Share an insight, caveat, or question.
Srikrishna et al. (2026) conducted a meta-analysis in Severe tricuspid regurgitation undergoing transcatheter tricuspid valve interventions (n=6,664). Cardiac implantable electronic device (CIED) status in TTVI vs. Patients undergoing TTVI without CIEDs was evaluated on In-hospital procedural mortality (RR 1.17, 95% CI 0.48-2.86). Cardiac implantable electronic device status did not significantly increase procedural mortality after transcatheter tricuspid valve intervention (RR 1.17; 95% CI 0.48-2.86).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: