Key result
Post-M-TEER iatrogenic ASD gradient predicts residual MR with good accuracy.
Why the study?
Assessing procedural success after transcatheter mitral edge-to-edge repair (M-TEER) remains challenging, and the association between iatrogenic atrial septal defect (iASD) gradient and post-procedural three-dimensional vena contracta area (3D-VCA) as a marker of residual mitral regurgitation severity was not clearly defined.
Does the intraoperative iatrogenic atrial septal defect (iASD) gradient accurately identify significant residual mitral regurgitation (post-procedural 3D-VCA >0.2 cm²) in patients undergoing M-TEER?
Observational (n=26)
No
Does the intraoperative iatrogenic atrial septal defect (iASD) gradient accurately identify significant residual mitral regurgitation (post-procedural 3D-VCA >0.2 cm²) in patients undergoing M-TEER?
An intraoperative iatrogenic ASD gradient ≥5 mmHg is a highly specific (93.3%) and simple marker for identifying significant residual mitral regurgitation (3D-VCA >0.2 cm²) immediately after M-TEER.
Answers are grounded in this paper and cite their sources.
Iatrogenic ASD gradient may flag residual MR after M-TEER; hypothesis-generating and requires validation in larger cohorts before adoption.
Introduction Assessment of procedural success following transcatheter mitral edge-to-edge repair (M-TEER), including non-invasive parameters, remains challenging. Purpose The association between iatrogenic atrial septal defect (iASD) gradient and post-procedural three-dimensional vena contracta area (3D-VCA) as a marker of residual mitral regurgitation severity has not been clearly defined. Methods In this prospective study, 26 patients who underwent M-TEER at a tertiary cardiovascular center were analyzed over the past year. Median age was 78 years (IQR 74–81.2), and 80.7% were male. Secondary mitral regurgitation was present in 50%, primary in 34.6%, and mixed etiology in 15.3%. The median post-procedural transmitral valve gradient was 2 mmHg (IQR 2–3), assessed by transesophageal echocardiography. Continuous-wave Doppler recordings across the iASD were obtained intraoperatively immediately after catheter withdrawal from the left atrium. The largest systolic 3D-VCA was quantified by direct planimetry from en face short-axis views using multiplanar reconstruction. Patients were stratified according to post-procedural 3D-VCA (≤0.2 vs >0.2, cm2). Diagnostic accuracy of the iASD gradient for identifying 3D-VCA >0.2cm2 was assessed using receiver operating characteristic (ROC) curve analysis, with optimal cutoff determined by the Youden index. Results Patients with post-procedural 3D-VCA >0.2 cm² demonstrated significantly higher iASD gradients than those with 3D-VCA ≤0.2 cm² (5.64±2.84 vs 3.07±1.10 mmHg, p=0.007). ROC analysis demonstrated good discriminatory ability for identifying 3D-VCA >0.2cm2 (AUC 0.81, 95% CI 0.61–0.97). An optimal iASD cutoff gradient ≥5 mmHg yielded a sensitivity of 63.6% and specificity of 93.3% for predicting 3D-VCA >0.2 cm². Conclusion The iASD gradient is associated with residual mitral regurgitation severity and shows good diagnostic accuracy for detecting 3D-VCA >0.2 cm². An iASD gradient ≥5 mmHg may serve as a simple and highly specific marker for immediate post-procedural assessment after M-TEER; however, validation in larger cohorts is required.
No takes yet. Share an insight, caveat, or question.
Kalompatsou et al. (2026) conducted an observational in Mitral regurgitation undergoing transcatheter mitral edge-to-edge repair (M-TEER) (n=26). Iatrogenic atrial septal defect (iASD) gradient (and post-procedural 3D-VCA >0.2 cm²) vs. Post-procedural 3D-VCA ≤0.2 cm² was evaluated on Post-procedural three-dimensional vena contracta area (3D-VCA) >0.2 cm² and associated iASD gradient (AUC 0.81, 95% CI 0.61-0.97, p=0.007). Iatrogenic ASD gradient after M-TEER predicted residual MR with good accuracy.
Synapse has enriched 10 related papers. Consider them for comparative context: