Why the study?
A substantial unmet clinical need persists for safe and effective transcatheter therapies in high-risk patients with severe tricuspid regurgitation. This first-in-human study aimed to assess the safety and feasibility of a novel dual-stent transcatheter tricuspid valve replacement system.
Is a novel transcatheter tricuspid valve replacement (TTVR) system safe and feasible in adult patients with severe, symptomatic tricuspid regurgitation who are unsuitable for open-heart surgery?
Is a novel transcatheter tricuspid valve replacement (TTVR) system safe and feasible in adult patients with severe, symptomatic tricuspid regurgitation who are unsuitable for open-heart surgery?
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
“Topaz's next-generation design has already improved upon existing TTVR treatments, with a procedure that is fast, exceptionally easy-to-use, and which has required few or no pacemaker implants.”
“The early clinical data from the US/Canadian EFS, the EU FIH, and the EU pivotal study have been encouraging and have significantly reduced the burden of procedural imaging.”
“We are highly encouraged by the results of this first-in-human trial. These initial findings serve as important validation for our ongoing clinical trials for Topaz in Europe and the US.”
This First-in-Human study demonstrates 100% procedural device success in reducing severe tricuspid regurgitation to mild or less with a novel dual-stent TTVR system, though with a 35% 30-day major adverse event rate in high-risk surgical patients.
Background/Introduction Despite increasing attention to the management of tricuspid regurgitation (TR), a substantial unmet clinical need persists for safe and effective transcatheter therapies in high-risk patients with severe TR. A novel transcatheter tricuspid valve replacement (TTVR) system has been specifically developed for the tricuspid position. Its innovative dual-stent design allows accommodation of a wide range of anatomical configurations while preserving optimal valve geometry and functional performance. Purpose The objective of this First-in-Human study is to assess the safety and feasibility of the TTVR system in patients with clinically significant tricuspid regurgitation. Methods This prospective, multicentre, single-arm, nonrandomized First-in-Human clinical investigation is conducted across eight sites in France, Belgium, and Switzerland. A total of 20 adult patients with severe, symptomatic tricuspid regurgitation who were considered unsuitable for open-heart surgery were enrolled. The primary safety endpoint is a composite endpoint measure that includes all-cause mortality, rehospitalization for heart failure, and reintervention for failed tricuspid intervention at 30 days. The primary performance endpoint is device success, defined as reduction of tricuspid regurgitation by at least 1 grade between the baseline and post-intervention evaluation (as assessed by the echo core laboratory), and no more than moderate tricuspid regurgitation. The study is closely monitored by an independent Data Safety Monitoring Committee (DMC) and an independent Clinical Events Committee (CEC), which adjudicates all adverse events. Additionally, all echocardiographic and computed tomography (CT) imaging are evaluated by independent core laboratories to ensure objective and consistent data assessment. Results In the TRICURE FIH a total of 20 patients (mean age 77 ± 6.6 years, 90 % female, TRI-SCORE 4.6 ± 2.5) were enrolled. All patients were symptomatic with NYHA ≥ II and had severe (grade ≥ 3) TR at baseline. The procedure time was 35 ± 16 minutes. At 30 days, the primary safety endpoint, a composite of major adverse events, was observed in 7 patients (35 %), including three all-cause deaths, three re-interventions (thereof two elective), and one hospitalization for heart failure. The primary performance endpoint was successfully achieved in all patients (100%), with all patients having a TR reduction of at least 3 grades, and none of the patients having more than mild TR post-procedure. No device-related pacemaker implant was reported. Conclusion(s) The primary endpoint results of the TRICURE FIH study provide convincing evidence of the feasibility and safety of this novel TTVR system. Additional outcomes will be assessed in the ongoing TRICURE EU PIVOTAL study.
No takes yet. Share an insight, caveat, or question.
J. Hausleiter (2026) studied Severe, symptomatic tricuspid regurgitation (n=20). Novel dual-stent transcatheter tricuspid valve replacement (TTVR) system was evaluated on Primary safety endpoint: composite of all-cause mortality, rehospitalization for heart failure, and reintervention for failed tricuspid intervention at 30 days; Primary performance endpoint: device success (TR reduction ≥1 grade and no more than moderate TR).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: