Key result
Fine-tuned ECG models detect rheumatic mitral stenosis with ~0.82 external AUROC.
Why the study?
Rheumatic mitral stenosis disproportionately affects low-resource settings with limited echocardiography availability, prompting evaluation of foundation model feasibility for detection using limited, indirectly labeled ECGs.
Does a fine-tuned electrocardiogram foundation model accurately detect ICD-coded rheumatic mitral stenosis across 12-lead, 6-lead, and 1-lead ECG configurations in US hospital cohorts?
Observational
Yes
Does a fine-tuned electrocardiogram foundation model accurately detect ICD-coded rheumatic mitral stenosis across 12-lead, 6-lead, and 1-lead ECG configurations in US hospital cohorts?
Fine-tuning an ECG foundation model enables moderate-to-high discrimination for detecting ICD-coded rheumatic mitral stenosis across 12-lead, 6-lead, and single-lead ECGs, supporting its potential as an echocardiography triage tool in resource-limited settings.
Answers are grounded in this paper and cite their sources.
May aid echocardiography triage for rheumatic mitral stenosis in low-resource settings; leaves open prospective validation before clinical use.
Background Rheumatic mitral stenosis (RMS) disproportionately affects low-resource settings where echocardiography is limited. We evaluated foundation model (FM) feasibility for RMS detection using limited, indirectly labeled ECGs. Methods An ECG-FM was fine-tuned using 804 RMS-positive ECGs per fold and externally validated across clinical and wearable lead configurations. Results Internal AUROCs were 0.89, 0.87, and 0.87, for 12-Lead, 6-Lead, and 1-Lead respectively. External AUROCs were 0.82, 0.80, and 0.77. Performance remained comparable across demographic subgroups. Conclusions FM fine-tuning enables RMS detection using limited ICD-derived labels, supporting further evaluation of reduced-lead ECG screening and echocardiography triage in resource-constrained settings.
No takes yet. Share an insight, caveat, or question.
Sriram et al. (2026) conducted an observational in Rheumatic Mitral Stenosis. Fine-tuned Electrocardiogram Foundation Model (ECG-FM) vs. ICD-9/10 diagnosis codes for Rheumatic Mitral Stenosis across 12-Lead, 6-Lead, and 1-Lead ECG formats was evaluated on Area under the receiver operating characteristic curve (AUROC) for detecting ICD-coded rheumatic mitral stenosis on 12-lead ECG (AUROC 0.89 (internal), AUROC 0.82 (external), 95% CI 0.88-0.90). Fine-tuned ECG foundation models detected rheumatic mitral stenosis with internal AUROCs of 0.89 (12L), 0.87 (6L), and 0.87 (1L), and external AUROCs of 0.82, 0.80, and 0.77.
Synapse has enriched 10 related papers. Consider them for comparative context: