Key result
Transvenous lead extraction for CIED infection achieves complete procedural success in ~83% of patients.
Why the study?
Infection of cardiac implantable electronic devices requires complete system removal, yet data on transvenous lead extraction from North African centers remain scarce.
What are the procedural success, clinical success, radiological success, and complication rates of transvenous lead extraction for cardiac implantable electronic device infection in a Moroccan tertiary center?
Observational (n=40)
No
What are the procedural success, clinical success, radiological success, and complication rates of transvenous lead extraction for cardiac implantable electronic device infection in a Moroccan tertiary center?
Transvenous lead extraction for CIED infection in a Moroccan tertiary center achieved 92.5% clinical success and 82.5% complete procedural success with a 5.0% major intraprocedural complication rate, demonstrating feasibility in a North African setting while highlighting the need for wider access to powered sheaths and rescue occlusion balloons.
Answers are grounded in this paper and cite their sources.
Supports feasibility in a Moroccan center; extends HRS-defined outcomes but leaves generalizability open pending larger studies.
Background: Infection of cardiac implantable electronic devices (CIEDs) requires complete system removal. Data on transvenous lead extraction (TLE) from North African centers remain scarce. Objective: To describe the clinical profile, procedural outcomes, and complications of TLE for CIED infection in a Moroccan tertiary center. Methods: We conducted a single-center observational study of all consecutive patients who underwent TLE for CIED infection at the Mohammed V Military Teaching Hospital, Rabat, between January 2018 and June 2026. Procedural data were recorded prospectively; clinical data were completed retrospectively from medical records. Outcomes were defined according to Heart Rhythm Society criteria. Results: Forty patients (mean age 68 years, range 45–92; 67.5% men) underwent 40 procedures for the removal of 76 leads. The mean lead dwell time was 96 ± 59.5 months, and 82.5% of patients had leads implanted for more than 5 years. Lead-related infective endocarditis was present in 23 patients (57.5%), and vegetations were seen on echocardiography in 19 (47.5%). Blood cultures were positive in 21 patients (52.5%), mostly with Staphylococcus aureus (9/21). Extraction used laser sheaths in 21 procedures (52.5%) 1 and simple traction in 19 (47.5%). Complete procedural success was achieved in 82.5% and clinical success in 92.5%. Complete radiological success was obtained for 81.6% of leads and partial success for 13.2%. Major intraprocedural complications occurred in two patients (5.0%), including one death from a superior vena cava tear (2.5%). Thirty-day mortality was 5.0%. Longer lead dwell time was associated with lower radiological success. Conclusion: TLE for CIED infection is feasible in our setting, with outcomes close to, though slightly below, those of high-volume centers. Wider access to powered sheaths, rescue balloons, and on-site surgical backup could further improve safety.
No takes yet. Share an insight, caveat, or question.
Ely et al. (2026) conducted an observational in Cardiac implantable electronic device (CIED) infection (n=40). Transvenous lead extraction (TLE) using laser sheaths or simple manual traction was evaluated on Complete procedural success. Transvenous lead extraction for CIED infection achieved 82.5% complete procedural success and 92.5% clinical success, with a 5.0% major intraprocedural complication rate and 5.0% 30-day mortality.
Synapse has enriched 10 related papers. Consider them for comparative context: