Key result
Rotational mechanical extraction enables safe complete removal of a 20-year-old ICD lead before S-ICD implantation.
Why the study?
Advanced age and prolonged lead dwell time significantly increase the risks of transvenous lead extraction (TLE) for CIED pocket infection. Reports of TLE in patients over 85 years with leads indwelling for two decades are exceedingly rare.
Case Report (n=1)
No
Demonstrates the feasibility and safety of using a rotational mechanical dilator sheath to extract a 20-year indwelling dual-coil passive-fixation ICD lead complicated by luminal occlusion and pocket infection in an 85-year-old patient, followed by S-ICD reimplantation.
Answers are grounded in this paper and cite their sources.
Supports individualized extraction and S-ICD strategies in high-risk elderly patients; leaves open need for prospective validation.
Background Complete removal of the cardiovascular implantable electronic device (CIED) system is the only curative treatment for CIED pocket infection. Advanced age and prolonged lead dwell time significantly increase the risks of transvenous lead extraction (TLE). However, reports of TLE in patients over 85 years with leads indwelling for two decades are exceedingly rare. Case presentation We report an 85-year-old man with a dual-coil passive-fixation implantable cardioverter-defibrillator (ICD) lead implanted 20 years prior, who presented with CIED pocket infection. Intraoperatively, occlusion of the mid-to-distal lead lumen was encountered during locking stylet advancement, precluding laser sheath extraction. An 11-F TightRail™ rotational mechanical dilator sheath was therefore used to dissect dense fibrotic tissue surrounding the lead in a layer-by-layer fashion, enabling complete lead extraction. After one week of antimicrobial therapy, a subcutaneous implantable cardioverter-defibrillator (S-ICD) was implanted due to persistent high risk of malignant ventricular arrhythmias and the risk of recurrent pocket infection associated with transvenous lead reimplantation. Conclusions This case represents a rare clinical scenario of TLE in an octogenarian with a 20-year indwelling dual-coil passive lead and multiple comorbidities. The successful outcome underscores the importance of meticulous preoperative risk stratification, multidisciplinary collaboration, and individualized procedural strategies for such high-risk patients.
No takes yet. Share an insight, caveat, or question.
Bao et al. (2026) conducted a case report in Cardiovascular implantable electronic device (CIED) pocket infection with a 20-year indwelling dual-coil passive-fixation ICD lead (n=1). Transvenous lead extraction using an 11-F TightRail rotational mechanical dilator sheath followed by subcutaneous ICD (S-ICD) implantation was evaluated on Complete transvenous lead extraction and complication-free recovery. Rotational mechanical sheath extraction and subsequent S-ICD implantation achieved complete removal of a 20-year-old dual-coil ICD lead with zero complications at 3 months in an 85-year-old man.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: