Key result
Voltage-guided stepwise PVI fails noninferiority to conventional PVI, with ~2-fold higher recurrence.
Why the study?
Extensive catheter ablation for atrial fibrillation may increase complication risks, motivating strategies that achieve pulmonary vein isolation with less lesion creation while preserving safety and effectiveness.
Does a voltage-guided stepwise pulmonary vein isolation approach prevent recurrence of atrial tachyarrhythmia within 12 months compared to conventional circumferential antral pulmonary vein isolation in patients undergoing first-time ablation for paroxysmal or non-paroxysmal atrial fibrillation?
RCT (n=130)
Voltage blinded to operators in control group
1:1
Yes
Does a voltage-guided stepwise pulmonary vein isolation approach prevent recurrence of atrial tachyarrhythmia within 12 months compared to conventional circumferential antral pulmonary vein isolation in patients undergoing first-time ablation for paroxysmal or non-paroxysmal atrial fibrillation?
A voltage-guided stepwise pulmonary vein isolation strategy failed to show non-inferiority and actually increased the risk of 12-month atrial tachyarrhythmia recurrence compared to conventional circumferential antral ablation.
Answers are grounded in this paper and cite their sources.
Voltage-guided stepwise PVI is not noninferior to conventional PVI; challenges voltage-based tailoring in first-time AF ablation.
Background Catheter ablation is an established rhythm control therapy for atrial fibrillation. However, as the extent of ablation increases, the risk of complications may also rise. This has motivated strategies that achieve pulmonary vein isolation with less lesion creation while preserving safety and effectiveness. Methods In this prospective, multicenter, randomized non-inferiority trial, 130 patients undergoing first-time ablation for paroxysmal or non-paroxysmal atrial fibrillation were assigned 1:1 to a voltage-guided stepwise pulmonary vein isolation approach or conventional circumferential antral pulmonary vein isolation with voltage blinded to operators. The primary end point was recurrence of atrial tachyarrhythmia within 12 months after ablation. Results At 12 months, recurrence occurred in 23/65 (35.4%) in the stepwise group versus 13/65 (20.0%) in the control group (risk difference 15.4 percentage points; 90% confidence interval, 2.7–28.1), and non-inferiority was not demonstrated (one-sided P=0.520). The treatment group had a higher risk of recurrent atrial tachyarrhythmia than the control group (hazard ratio, 2.05; 95% confidence interval, 1.04–4.06), with longer procedure times and more frequent acute pulmonary vein reconnection after the initial lesion set. The treatment group had fewer acute complications than the control group (1.5% versus 9.2%; P=0.115), and esophageal thermal injury was observed only in the control group (3 cases). Conclusions Voltage-guided stepwise pulmonary vein isolation failed to demonstrate non-inferiority to conventional circumferential antral pulmonary vein isolation for 12-month atrial tachyarrhythmia recurrence. ClinicalTrials.gov ID: NCT07354737
No takes yet. Share an insight, caveat, or question.
Kim et al. (2026) conducted an RCT in Paroxysmal or non-paroxysmal atrial fibrillation (n=130). Voltage-guided stepwise pulmonary vein isolation vs. Conventional circumferential antral pulmonary vein isolation was evaluated on Recurrence of atrial tachyarrhythmia within 12 months after ablation (HR 2.05, 95% CI 1.04-4.06, p=0.520 for noninferiority). Voltage-guided stepwise PVI failed to show noninferiority to conventional PVI for 12-month atrial tachyarrhythmia recurrence.
Synapse has enriched 10 related papers. Consider them for comparative context: