Why the study?
Although HFpEF is prevalent among patients on renal replacement therapy, electrocardiographic and echocardiographic predictors of HFpEF in this population are not fully identified.
Does the electrocardiographic Sokolow-Lyon product improve the identification of heart failure with preserved ejection fraction compared to or alongside echocardiography in patients on renal replacement therapy?
Observational (n=83)
Single-blind
No
Does the electrocardiographic Sokolow-Lyon product improve the identification of heart failure with preserved ejection fraction compared to or alongside echocardiography in patients on renal replacement therapy?
The Sokolow-Lyon product is a simple, widely available ECG marker that is independently associated with HFpEF and correlates with cardiac structural and functional abnormalities, potentially aiding HFpEF diagnosis in dialysis patients when echocardiographic diastolic assessment is equivocal.
Answers are grounded in this paper and cite their sources.
May support Sokolow-Lyon product as adjunct for HFpEF detection in renal replacement therapy; leaves open prospective validation before clinical use.
Background: While heart failure with preserved ejection fraction (HFpEF) is prevalent among patients on renal replacement therapy (RRT), predictors of HFpEF are not fully identified. In this prospective study, we assessed electrocardiographic (ECG) and echocardiographic predictors of HFpEF in patients on RRT. Methods: A total of 83 consecutive RRT patients with ejection fraction ≥50% (mean age 61±13 years, 43% female, 88% on hemodialysis) underwent 12-lead ECG, including Sokolow-Lyon product (SLP) calculation, as well as comprehensive echocardiography with guideline-recommended diastolic function assessment. Results: HFpEF was diagnosed in 20% of patients who had significantly higher values of SLP. Normal and indeterminate diastolic function was detected in 18% and 41% of patients with HFpEF, respectively. SLP showed moderately strong correlations with left ventricular mass index (r=0.39, p<0.001), left atrial volume index (r=0.46, p<0.001), mitral E/e' ratio (r=0.39, p<0.001), and maximal tricuspid regurgitation velocity (r=0.47, p<0.001). Patients with diastolic dysfunction (2311±787 mm/ms) and indeterminate diastolic function (2198±933 mm/ms) had higher values of SLP than those with normal diastolic function (1575±675 mm/ms, p=0.001). With a cutoff value of 2038 mm/mV, SLP showed a good sensitivity (77%) and specificity (70%) for identifying HFpEF. In multivariate analysis, only SLP [odds ratio (OR) 1.001, 95% confidence interval (CI) 1.000-1.002, p=0.030] and coronary artery disease (OR 33.091, 95% CI 4.097 -267.266, p<0.001) remained independently associated with HFpEF. Conclusions: SLP is associated with structural and functional cardiac abnormalities in HFpEF patients on RRT. This simple ECG marker is associated with HFpEF and may complement echocardiographic assessment in patients on RRT.
No takes yet. Share an insight, caveat, or question.
Scepanovic et al. (2026) conducted an observational in End-stage renal failure on renal replacement therapy with preserved ejection fraction (n=83). Sokolow-Lyon product vs. Echocardiographic parameters and lower Sokolow-Lyon product values was evaluated on Heart failure with preserved ejection fraction (HFpEF) (OR 1.001, 95% CI 1.000-1.002, p=0.030).
Synapse has enriched 10 related papers. Consider them for comparative context: