Key result
AI echocardiography software correlates strongly with physician LVEF measurements and moderately for GLS.
Why the study?
Does artificial intelligence software accurately evaluate left ventricular ejection fraction and global longitudinal strain compared to specialized physician assessment in patients undergoing echocardiography?
Cross-Sectional (n=136)
No
Does artificial intelligence software accurately evaluate left ventricular ejection fraction and global longitudinal strain compared to specialized physician assessment in patients undergoing echocardiography?
Automated AI analysis of echocardiograms provides rapid measurements of left ventricular ejection fraction and global longitudinal strain that correlate significantly with manual assessments by specialized physicians.
Answers are grounded in this paper and cite their sources.
AI correlations support hypothesis generation for automated echocardiography; leaves open prospective validation before any clinical adoption.
Background: In recent years, there has been a significant focus on the development of artificial intelligence (AI) applications in healthcare. However, current scientific evidence is still not convincing enough for the general public and the medical community to widely adopt AI in clinical practice. Objective: We conducted this study to investigate the correlation between left ventricular function indices assessed by AI and those evaluated by physicians. Methods: This cross-sectional descriptive study was conducted on 136 patients who attended and received treatment at Hue University of Medicine and Pharmacy Hospital from April 2022 to June 2023. Using QLAB version 15, Philips Healthcare. Results: The AI software accurately identified 98.5% of the echocardiographic cine-loops. However, there were about 1.5% of cine-loops that the software failed to recognize. The sensitivity of Ejection Fraction (EF) calculated by AI was 73.3%, specificity was 81.3%, and accuracy stood at 78.6%. A strong positive correlation was observed between EF measured by AI and that assessed by physicians, r = 0.701, p < 0.01. The sensitivity of Global Longitudinal Strain (GLS) calculated by AI was 42.1%, specificity was 84.8%, and accuracy was 67.6%. A moderate positive correlation was found between GLS measured by AI and physician's assessment, r = 0.460, p < 0.01. Conclusion: The use of AI software for evaluating left ventricular function through ejection fraction and global longitudinal strain is rapid and yields results comparable to cardiologists' echocardiographic assessments. The AI-powered software holds a promising and feasible future in clinical practice.
No takes yet. Share an insight, caveat, or question.
Doan et al. (2024) conducted a cross-sectional in Patients undergoing echocardiography for left ventricular function assessment (n=136). Automated AI software (Philips QLAB version 15.0) echocardiographic analysis vs. Manual assessment by specialized cardiac ultrasound physicians was evaluated on Correlation between AI-measured and physician-assessed left ventricular Ejection Fraction (EF) and Global Longitudinal Strain (GLS) (r = 0.701 for EF; r = 0.460 for GLS, p=<0.01). AI software (QLAB 15) measurements correlated strongly with physician assessments for left ventricular ejection fraction and moderately for global longitudinal strain.
Synapse has enriched 10 related papers. Consider them for comparative context: