Key result
Bicuspid anatomy is linked to ~2-mmHg higher residual gradients vs tricuspid valves after Venus-A TAVR.
Why the study?
Differences in prosthetic valve deformation and postprocedural hemodynamic performance between bicuspid and tricuspid aortic valve anatomy after transcatheter aortic valve replacement with the Venus-A prosthesis required evaluation.
Does bicuspid aortic valve anatomy affect prosthetic valve deformation and hemodynamic performance compared to tricuspid aortic valve anatomy in patients undergoing transcatheter aortic valve replacement with the Venus-A prosthesis?
Cohort (n=212)
Does bicuspid aortic valve anatomy affect prosthetic valve deformation and hemodynamic performance compared to tricuspid aortic valve anatomy in patients undergoing transcatheter aortic valve replacement with the Venus-A prosthesis?
In patients undergoing TAVR with the Venus-A prosthesis, bicuspid aortic valve anatomy results in greater prosthetic ellipticity and slightly higher residual transvalvular gradients compared to tricuspid anatomy, despite comparable prosthetic expansion and paravalvular leak rates.
Answers are grounded in this paper and cite their sources.
Bicuspid TAVR may warrant anatomy-specific planning; observational data leaves open effects on durability and events.
Background This study compared prosthetic valve deformation and postprocedural hemodynamic performance between bicuspid and tricuspid aortic valve anatomy after transcatheter aortic valve replacement with the Venus‐A prosthesis. Methods We retrospectively evaluated patients who underwent transcatheter aortic valve replacement between 2012 and 2022 and underwent postoperative computed tomography within 1 year. Predischarge echocardiographic assessments included the mean transvalvular gradient and paravalvular leak. Computed tomography measurements included expansion ratio, ellipticity, implantation depth, asymmetric leaflet expansion, and hypoattenuated leaflet thickening. The leaflet inflow and valve waist were collectively defined as the functional valve portion. Results Among 212 patients (106 bicuspid and 106 tricuspid), the mean age was 74.2±7.6 years, and 43.9% were women. Patients with bicuspid anatomy had a significantly lower oversizing ratio and underwent balloon predilation and postdilation more frequently than those with tricuspid anatomy. Residual transvalvular gradients were higher with bicuspid than tricuspid anatomy (12.0 [interquartile range, 8.2–17.0] versus 10.0 [7.2–14.0] mm Hg; P =0.014), whereas moderate to severe paravalvular leak did not differ significantly. Prosthetic ellipticity was greater in bicuspid anatomy, but expansion ratios, including those within the functional valve portion, did not differ significantly. Implantation depth, asymmetric leaflet expansion, and hypoattenuated leaflet thickening incidence also did not differ significantly. Conclusions Following Venus‐A implantation, bicuspid anatomy was associated with greater prosthetic ellipticity and higher residual gradients, despite no significant difference in prosthetic expansion.
No takes yet. Share an insight, caveat, or question.
Feng et al. (2026) conducted a cohort in Aortic valve disease undergoing transcatheter aortic valve replacement with the Venus-A prosthesis (n=212). Bicuspid aortic valve anatomy undergoing Venus-A TAVR vs. Tricuspid aortic valve anatomy undergoing Venus-A TAVR was evaluated on Residual mean transvalvular gradient (p=0.014). Bicuspid aortic valve anatomy was associated with higher residual transvalvular gradients than tricuspid anatomy after Venus-A TAVR and greater prosthetic ellipticity.
Synapse has enriched 10 related papers. Consider them for comparative context: