Key result
Contrast-only CTA matches multiphase CTA accuracy for acute aortic syndromes while cutting radiation dose ~32%.
Why the study?
The feasibility of omitting the unenhanced phase in a contrast-only CTA protocol compared with a conventional multiphase protocol for detecting and characterizing acute aortic pathologies and reducing radiation dose needed evaluation.
Does a contrast-only CTA protocol (omitting the unenhanced phase) provide non-inferior diagnostic detection of acute aortic pathologies while reducing radiation dose compared to a standard multiphase CTA protocol in patients with confirmed aortic pathology?
Cohort (n=160)
Independent evaluation by two experienced radiologists with a 4-week washout interval between protocols
No
Does a contrast-only CTA protocol (omitting the unenhanced phase) provide non-inferior diagnostic detection of acute aortic pathologies while reducing radiation dose compared to a standard multiphase CTA protocol in patients with confirmed aortic pathology?
Omitting the unenhanced phase in aortic CTA reduces radiation dose by ~32% while maintaining non-inferior diagnostic detection of major aortic pathologies, supporting its selective use in serial surveillance imaging of established aortic disease.
Answers are grounded in this paper and cite their sources.
Contrast-only CTA may enable lower-radiation aortic imaging in established disease; leaves open prospective validation before changing acute protocols.
Objectives To evaluate the feasibility of a contrast-only computed tomography angiography (CTA) protocol versus a conventional multiphase protocol for detecting and characterizing acute aortic pathologies, and reducing radiation dose. Materials & methods This retrospective study included 160 patients who underwent multiphase CTA for evaluating acute aortic syndrome. Two readers independently evaluated 640 predefined aortic segments for the presence of aneurysms, dissections, intramural hematomas (IMH), and penetrating atherosclerotic ulcers (PAU). Non-inferiority was assessed using generalized estimating equations with a prespecified 5% margin. Inter-protocol and inter-reader agreements were calculated using Cohen’s kappa. Radiation dose also was compared . Results The contrast-only protocol demonstrated non-inferiority to the full protocol for detecting all major aortic pathologies, with all confidence intervals falling within the 5% margin. Detection rates were identical for aneurysms (33.6% vs. 33.6%; p = 1.000) and similar for dissections (15.6% vs. 15.9%; p = 0.500). Detection rates were slightly higher with the contrast-only protocol for IMH (5.8% vs. 5.0%) and PAU (5.8% vs. 4.7%), primarily reflecting false-positive interpretation. Interprotocol agreement was perfect for aneurysm shape and rupture status (kappa = 1.000) but lower for mural thrombus characterization (kappa = 0.703). The contrast-only protocol achieved a 32.1 ± 5.7% reduction in mean DLP and 32.4 ± 4.5% for CTDI vol (both, p < 0.001). Conclusion In patients with acute aortic pathology, a contrast-only protocol demonstrated non-inferior diagnostic performance to the full multiphase protocol, with comparable reader agreement and a 32% reduction in radiation dose. These findings suggest that omitting the unenhanced phase may be feasible in selected clinical scenarios, particularly in patients undergoing serial surveillance imaging, where cumulative dose reduction is a priority.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2026) conducted a cohort in Confirmed acute aortic pathology (aneurysm, classic aortic dissection, intramural hematoma, or penetrating atherosclerotic ulcer) (n=160). Contrast-only CT angiography (CTA) protocol (arterial and delayed phases, omitting unenhanced phase) vs. Conventional full multiphase CTA protocol (unenhanced, arterial, and delayed phases) was evaluated on Diagnostic non-inferiority in detection rates across 640 aortic segments (specifically aortic dissection detection rate and radiation dose reduction) (Difference in detection proportion -0.003 for dissection; DLP reduction 32.1 ± 5.7%, 95% CI -0.003 to 0.002, p=0.500 (dissection); <0.001 (radiation dose reduction)).
Synapse has enriched 10 related papers. Consider them for comparative context: