Key result
Modified robotic beating-heart ASD repair is associated with ~4 minutes shorter CPB time versus thoracoscopy.
Why the study?
The study aimed to evaluate a modified robot-assisted technique for beating-heart ASD repair and to compare its perioperative outcomes against thoracoscopic repair.
Does a modified robot-assisted technique for beating-heart atrial septal defect repair improve cardiopulmonary bypass time and perioperative outcomes compared to thoracoscopic repair in patients with ASD unsuitable for device closure?
Cohort (n=311)
No
Does a modified robot-assisted technique for beating-heart atrial septal defect repair improve cardiopulmonary bypass time and perioperative outcomes compared to thoracoscopic repair in patients with ASD unsuitable for device closure?
Once the learning curve of 66–81 cases is surpassed, modified robot-assisted beating-heart ASD repair achieves shorter cardiopulmonary bypass times than thoracoscopic repair despite treating larger and more anatomically complex defects, with equivalent safety and 1-year efficacy.
Answers are grounded in this paper and cite their sources.
May support robotic ASD repair in complex cases after proficiency; leaves open need for RCTs before wider adoption.
Objective To evaluate a modified robot-assisted technique for atrial septal defect (ASD) repair on beating heart and to compare perioperative outcomes with thoracoscopic repair. Methods 198 patients with ASD underwent modified ASD repair using the Da Vinci robotic surgical system on beating heart in the Department of Cardiovascular Surgery of the First Affiliated Hospital with Nanjing Medical University. Cumulative sum (CUSUM) analysis was used to build learning curves for operation time and cardiopulmonary bypass (CPB) time. Patients operated after both curves had plateaued formed the robotic group (n = 117); 113 patients treated thoracoscopically during the same period served as the comparison group. Results The learning curves for operation time and CPB time were 81 cases and 66 cases respectively. ASD diameter and pulmonary artery systolic pressure were higher in the robotic group, which also contained seven patients with partial anomalous pulmonary venous connection (PAPVC) and one with anomalous drainage of the inferior vena cava. CPB time was shorter in the robotic group. Operation time, mechanical ventilation time, intensive care unit stay, postoperative hospital stay and 24-hour chest drainage did not differ. Echocardiography at 3, 30 and 90 days and at one year showed no residual shunt or tricuspid regurgitation in either group. Conclusions The modified robot-assisted technique for beating-heart ASD repair is safe and reproducible. Once the learning curve is complete, CPB time is shorter than with thoracoscopy despite greater anatomical complexity, and the technique offers a valid minimally invasive option for defects that are unsuitable for device closure.
No takes yet. Share an insight, caveat, or question.
Feng et al. (2026) conducted a cohort in Atrial septal defect (ASD) (n=311). Modified robot-assisted beating-heart atrial septal defect repair (post-learning curve) vs. Thoracoscopic beating-heart atrial septal defect repair was evaluated on Cardiopulmonary bypass (CPB) time (minutes) (p=0.002). Modified robotic beating-heart ASD repair after an 81-case learning curve resulted in shorter CPB time than thoracoscopy despite greater anatomical complexity.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: