Fast‐frequency pulsed welding power supplies require current regulation across changing load and dc‐bus conditions. This study develops an application‐oriented linear active disturbance rejection control (LADRC) implementation for a dual‐path phase‐shifted full‐bridge (PSFB) source rated at 400 A dc plus 150 A pulsed current. A control‐oriented model distinguishes load‐dependent damping, commutation duty loss, and analog‐to‐digital converter (ADC) and pulse‐width modulation (PWM) scaling from the nominal controller gain. A first‐order regulator with a second‐order linear extended state observer is implemented on an STM32G474 with a 20‐μs control period. Hardware comparisons include a local incremental proportional–integral (PI) gain scan and repeated electrical tests. In the 400 A branch, the 50 and 100 A step rise times decrease by 25.1% and 28.9%, respectively, although LADRC is not faster at every operating point. Between fixed dc‐bus levels of 544 and 420 V, the mean rise‐time drift over the 30–200 A subset is 15.7% for LADRC and 56.0% for PI. In the pulse branch, the tabulated pulse counts indicate a 45.5% reduction in mean recovery time. The mean amplitude coefficient of variation across three 100‐pulse acquisitions decreases from 4.13% to 1.28% at the tested 50 A operating point. These results establish application‐specific electrical performance, rather than parameter‐independent closed‐loop dynamics or validated welding‐quality gains.