Answers are grounded in this paper and cite their sources.
This study investigates the electrical degradation behaviour of a 48 V valve-regulated lead–acid (VRLA) battery pack designed for e-rickshaw applications. The pack was subjected to continuous cycling under a severe duty profile derived from the IEC 63,193 standard, representing long-range operation under heavy load and steep-gradient driving conditions. The battery pack achieved peak performance corresponding to a maximum running time of approximately 162 min between cycles 110 and 150. However, after 164 cycles, the running time collapsed abruptly from 137 min to only 6 min, indicating sudden catastrophic failure. Several precursor warning signatures were identified prior to this collapse, including reduced charge acceptance, progressive suppression of rebound voltage, accelerated decline in energy efficiency, and a pronounced transformation of the discharge voltage profile. These degradation indicators consistently converged around the ~ 117th cycle, marking a clear inflection point at which aging transitioned from gradual to accelerated behaviour. The systematic evolution of the discharge voltage profile serve as a distinctive electrochemical fingerprint of positive active material (PAM) degradation. Based on these observations, a Dual-Regime Discharge behaviour is proposed to describe the transition from high-voltage-dominated discharge to low-voltage-dominated discharge as degradation progresses.
No takes yet. Share an insight, caveat, or question.
Mayavan et al. (2026) studied this question.