Answers are grounded in this paper and cite their sources.
Large timber constructions may adopt composite structures with reinforcement materials and joints. Hybrid timber-to-steel and timber-to-plybamboo connections using self-tapping screws represent an effective composite solution. However, the effects of key design parameters and existing models for the shear behavior of these connections remain unclear, limiting rational design. For this purpose, the shear behavior of screw connections for timber-to-steel and timber-to-plybamboo joints was experimentally investigated, considering connecting plate type, screw diameter, screw number, and screw angle relative to the grain direction. The shear capacity of both types of joints increased with screw diameter and number. For 25°-inclined screws with diameters of 6, 8, and 10 mm, the average shear capacity of timber-to-steel joints was approximately 16.01%, 1.68%, and 11.31% higher than that of joints with plybamboo plate, respectively. The ductility of both joint types decreased with larger screw diameters and smaller screw angles. An analytical model that addressed the specific failure mode was proposed to predict the shear capacity of the timber-to-steel joints adequately, whereas Mirdad's model predicted stiffness with limited accuracy and was inapplicable to 90° connections. These findings clarify the parameter-dependent shear behavior of hybrid self-tapping screw connections and provide a validated analytical reference for their design.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: