The effects of elevated temperature and bond geometry on fibre-reinforced polymer (FRP)-to-timber joints remain insufficiently understood. This study examined the bond behaviour of carbon-fibre-reinforced polymer (CFRP) and basalt-fibre-reinforced polymer (BFRP) sheets bonded to Northeast larch timber. Ninety single-lap shear specimens were tested, covering two FRP types, five bond geometries and three temperatures, with three replicates per group. Reference tests were conducted at the prevailing laboratory temperature of approximately 30 °C, and heated specimens were tested at 60 °C and 90 °C. Mean ultimate loads decreased with increasing temperature for every geometry. Increasing bond width from 30 to 70 mm increased mean capacity at 30 °C by 148.1% for CFRP and 123.6% for BFRP. The effect of bond length depended on material and temperature, with no consistent increase across all configurations. Failure locations varied between the timber–adhesive boundary, FRP- adhesive boundary and adhesive layer. An empirical temperature-dependent model achieved R2 values of 0.928 for calibration and 0.851 for internal cross-validation, with corresponding mean absolute percentage errors of 15.2% and 17.6%. These findings demonstrate that temperature and bond geometry jointly influence capacity, while application of the model beyond the tested configurations requires independent validation.