The flow demand of multi-branch pipeline systems in air-suction seeders directly affects airflow stability at seed metering devices and fan capacity matching. To clarify the quantitative relationship between pipeline structural parameters and main pipe flow demand, and to avoid fan overcapacity and increased energy consumption caused by empirical estimation or single-branch extrapolation, the pneumatic system of an air-suction precision hill-drop rice seeder was investigated using mechanistic analysis, numerical simulation, and experimental validation. The effects of main pipe inner diameter and length, header inner diameter, branch pipe inner diameter and length, branch pipe spacing, and inlet flow rate of branch pipe 1 were examined. Results showed that these factors mainly altered branch pipe flow distribution by changing header pressure. Flow turning, jet mixing, and local resistance losses induced by successive confluence at tee junctions, together with frictional losses, governed the pressure-gradient variation along the header. A main pipe flow prediction model was established using dimensional analysis and interpolation. Predicted and experimental values agreed well (R2 > 0.99), and prediction errors were within ±10% over the investigated parameter range. The model effectively characterized main pipe flow demand under different pipeline configurations and operating conditions, providing technical support for low-energy pneumatic-system design and fan capacity matching in air-suction seeders.