Answers are grounded in this paper and cite their sources.
We compared nine ultra-high-performance concrete (UHPC) mixtures, including a plain reference and eight mixtures containing 2.0 vol% short steel, long steel, or polyvinyl alcohol (PVA) fibers in different proportions. The equal-volume steel blend M4 had a flexural strength of 27.0 MPa and a reported fracture energy of 31.5 kJ/m2, 25.3% and 52.5% above the corresponding volume-weighted single-steel baselines. M7 had the highest reported compressive strength and elastic modulus, at 151.6 MPa and 48.0 GPa. Replacing 0.25 vol% short steel with long steel from M7 to M8 was associated with a rise in flexural strength from 29.2 to 30.4 MPa and in reported fracture energy from 35.8 to 38.6 kJ/m2. The reported compressive strength was 1.2% lower. In M8, PVA occupied 12.5% of the fiber volume and accounted for 89.3% of the calculated filament count and 45.5% of the calculated lateral interface area. The mixture comparisons suggest that longer potential steel-fiber embedment may contribute to resistance during crack opening.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: