Answers are grounded in this paper and cite their sources.
Converting stiffened flanges to unstiffened details can simplify fabrication and assembly for emergency replacement. This study proposes a dual-response assessment procedure combining global displacement and connection rotation matching with local load-transfer checks. Project-based nonlinear finite element models establish a common compression–bending reference. Normalized root-mean-square errors guide thickness selection and comparisons of flange outside diameter and bolt circle diameter. Contact evolution, interface opening and bolt-force histories explain the associated load redistribution. At an eccentricity of 125 mm, a 14 mm unstiffened flange gives displacement and rotation errors of 3.37% and 3.72%, respectively, relative to a 6 mm stiffened reference. The constant-length comparison confirms the 14 mm stiffness-matching candidate. Resistance checks at the research load target identify the need to revise its original class 8.8 M12 bolt configuration and associated connection detailing. The procedure therefore combines response-based selection with a separate component-resistance assessment for replacement design.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: