Key result
Peak LV pressure during aortic valvuloplasty correlates strongly with LVEF and drops with heart failure.
Why the study?
Peak left ventricular pressure during balloon inflation had previously been obtained only in experimental animal studies, and the determinants of ventricular pressure development in response to increased loading conditions in humans with severe aortic stenosis needed to be defined.
Does peak left ventricular pressure measured during percutaneous aortic balloon valvuloplasty correlate with echocardiographic measures of left ventricular function and clinical heart failure status in patients with severe aortic stenosis?
Cross-Sectional (n=20)
Does peak left ventricular pressure measured during percutaneous aortic balloon valvuloplasty correlate with echocardiographic measures of left ventricular function and clinical heart failure status in patients with severe aortic stenosis?
Peak left ventricular systolic pressure measured during aortic balloon valvuloplasty is a simple, reproducible hemodynamic index in humans that correlates closely with echocardiographic measures of left ventricular function and clinical heart failure in severe aortic stenosis.
Answers are grounded in this paper and cite their sources.
May inform procedural hemodynamics in aortic valvuloplasty; hypothesis-generating and requires prospective validation before clinical use.
Peak left ventricular pressure during balloon inflation was measured in 20 patients who underwent balloon valvuloplasty for severe aortic stenosis to define the determinants of ventricular pressure development in response to increased loading conditions. The peak left ventricular pressure ranged from 150 +/- 5 to 386 +/- 22 mm Hg (mean +/- SD), was reproducible in each patient with each balloon inflation (mean coefficient of variation 7.8%) and correlated with concurrent echocardiographic measurements of ejection fraction (r = 0.89, p = 0.0001) and mass/volume ratio in systole (r = 0.91, p = 0.0001) or diastole (r = 0.88, p = 0.0001). Thirteen patients with class II or more severe congestive heart failure had lower values for peak left ventricular pressure than did those without failure (225 +/- 46 versus 305 +/- 45 mm Hg, p = 0.002), whereas no difference in rest left ventricular systolic pressure was seen between the two groups. The measurement of peak left ventricular pressure was inversely related to rest mean circumferential end-systolic wall stress (r = 0.52, p = 0.046). Thus, peak left ventricular systolic pressure measured during aortic valvuloplasty in humans correlates closely with traditional measures of left ventricular function. This measurement, which previously has been obtained only in experimental animal studies, is a simple and reproducible hemodynamic index that may provide new insights in studies of ventricular function and congestive heart failure in aortic stenosis.
No takes yet. Share an insight, caveat, or question.
Bittl et al. (1989) conducted a cross-sectional in Severe aortic stenosis (n=20). Peak left ventricular pressure measurement during percutaneous aortic balloon valvuloplasty vs. Patients without congestive heart failure (n=7) vs. patients with class II or more severe congestive heart failure (n=13) was evaluated on Peak left ventricular pressure during balloon inflation and its correlation with echocardiographic left ventricular ejection fraction (r = 0.89, p=0.0001). Peak LV pressure during aortic balloon valvuloplasty correlated strongly with LVEF and was lower in patients with class ≥II HF than without.
Synapse has enriched 10 related papers. Consider them for comparative context: