This study investigates the potential of ultrasonic pulse velocity (UPV) and acoustic tests for the nondestructive evaluation of structural lightweight concrete after exposure to elevated temperatures. The main contribution is the combined assessment of these techniques and the establishment of relationships between their dynamic parameters and residual mechanical properties under different thermal exposure and cooling conditions. The results showed a systematic degradation with increasing temperature, with longitudinal wave velocity decreasing from approximately 3400 m/s at ambient temperature to 1450–1600 m/s at 800 °C, while the dynamic modulus obtained from acoustic tests decreased to approximately 15–20% of its initial value. Strong correlations were obtained between the dynamic moduli from UPV and acoustic tests (R² = 0.95–0.93), as well as between dynamic and residual static properties (R² = 0.90–0.94). A strong correlation was also obtained between residual UPV and compressive strength (R² = 0.95). The results demonstrate the potential of combining UPV and acoustic tests for post-fire assessment of structural lightweight concrete and highlight the need for material-specific correlations for reliable evaluation.