Key result
Blood acceleration metric strongly correlates with CT-derived FFR in mild-to-moderate carotid stenosis.
Why the study?
Invasive fractional flow reserve carries risks that impede its use in cerebral vessels, while computed tomography simulation approaches to assess functional severity of carotid artery stenoses are time-consuming and difficult to integrate into clinical workflows.
Does the blood acceleration metric (BAM) correlate with FFRCT in assessing the functional severity of mild to moderate carotid artery stenoses?
Observational (n=27)
Does the blood acceleration metric (BAM) correlate with FFRCT in assessing the functional severity of mild to moderate carotid artery stenoses?
The blood acceleration metric (BAM) shows a strong negative correlation with FFRCT (R=-0.85) in 27 mild to moderate carotid stenoses, suggesting potential as a simpler surrogate for assessing functional stenosis severity.
Answers are grounded in this paper and cite their sources.
BAM may support non-invasive FFR assessment in carotid stenosis; leaves open validation for stroke risk stratification.
Purely morphological assessment of an arterial stenosis is not sufficient to adequately evaluate its functional significance. The metric of fractional flow reserve (FFR) is the gold standard for assessing coronary artery stenoses. However, the risks associated with catheterization and induction of hyperemia needed to measure FFR impede its application to cerebral vessels. Approaches based on a combination of computed tomography (CT) with computer simulations have been proposed to address this issue, yielding an estimate of fractional flow reserved (FFRCT). While promising, they are time-consuming and difficult to integrate into established clinical workflows. Here, we propose a new, easily derivable parameter termed the blood acceleration metric (BAM). It incorporates readily measurable morphological and hemodynamic features, such as minimum stenosis diameter and peak systolic velocity, to assess the functional severity of carotid artery stenoses. Preliminary assessment on 27 mild to moderate stenoses indicates a strong negative correlation (R=-0.85) between BAM and FFRCT. BAM should be further evaluated as a potential surrogate for FFR and, thereby, as a possible predictor of stroke risk.
No takes yet. Share an insight, caveat, or question.
Lovera et al. (2026) conducted an observational in Carotid artery stenosis (n=27). Blood acceleration metric (BAM) vs. CT-derived fractional flow reserve (FFRCT) was evaluated on Correlation between blood acceleration metric (BAM) and FFRCT (R=-0.85). The blood acceleration metric (BAM) demonstrated a strong negative correlation with CT-derived fractional flow reserve (FFRCT) in 27 mild to moderate carotid artery stenoses.