Answers are grounded in this paper and cite their sources.
The paper analyses the crack bridging ability of waterproofing coatings used beneath ceramic tiling bonded with adhesives in tests carried out using the test method specified in EN 14891. The study examines 11 products divided into 3 material groups: water dispersions, resin and cement-polymer coatings. The highest resistance in this respect is shown by resin coatings; the least effective are water-dispersion-based coatings. Unfortunately, most tested products do not guarantee waterproofing durability under the climatic conditions of Poland, cracking at elongations of less than 0.75 mm. In addition, it was established that a change in the test speed of the concrete-coating sets from 0.05 mm·min−1 (according to EN 1062-7) to 0.15 mm·min−1 (according to EN 14891) does not significantly affect the elongation at which the first damage occurs, especially at sub-zero temperatures. It is also not possible to draw conclusions about the ability of the coatings to bridge cracks in concrete from the results of mechanical tensile tests performed on thin films, e.g., in accordance with EN ISO 527-1 and EN ISO 527-3.
No takes yet. Share an insight, caveat, or question.
Francke et al. (2026) studied this question.