Answers are grounded in this paper and cite their sources.
Slurry mixing influences the electrode mesostructure and performance of Li-ion batteries. Coarse-grained molecular dynamics (CGMD) can model slurry behavior, but its predictions depend strongly on force-field (FF) parameters. This study presents a design of experiments (DOE)-based workflow to assess Lennard-Jones and Granular Hertz parameters in an LiNi0.33Mn0.33Co0.33O2 cathode slurry model containing 85 wt% active material and 15 wt% carbon–binder domain at a target slurry solid content of 46 wt%. Literature-based parameter sets yielded simulated densities of 1.064–1.931 g cm−3. Fractional factorial screening identified the normal contact elastic constant (kn) as the dominant density-controlling parameter, followed by the active-material interaction distance (σAM). DOE-guided optimization yielded a density of 1.407 g cm−3, closer to the experimental value of 1.550 ± 0.002 g cm−3 than the baseline literature sets. The density-optimized parameters were independently evaluated using non-equilibrium molecular dynamics (NEMD) viscosity simulations. At 500 s−1, the predicted steady-state viscosity deviated by 23.2% from experiment. At 65 s−1, large internal stress fluctuations, box flipping, and atom loss prevented reliable viscosity estimation. The workflow provides a systematic, computationally efficient approach to FF parameter selection while identifying limitations of low-shear NEMD predictions.
No takes yet. Share an insight, caveat, or question.
Gençtürk et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: