Answers are grounded in this paper and cite their sources.
COMSOL Multiphysics (version 6.3) simulations were performed in the current work to investigate the effects of Fe3+, Cu2+, and their coupled contamination on the local current density, electrolyte potential, Ni2+ distribution, and coating thickness uniformity during the nickel electrodeposition process. The results show that Fe3+ slightly reduces the mean coating thickness with limited uniformity variation, while Cu2+ mainly degrades current-density and thickness uniformity at low concentration and then stabilizes. Under coupled Fe3+-Cu2+ contamination, the maximum of uniformity metrics occurred at different concentration combinations, indicating a nonlinear coupled effect rather than simple linear superposition. These results indicate that Fe3+ and Cu2+ mainly affect deposition uniformity and thickness response, while the overall fields change only slightly. Therefore, both ions should be jointly controlled and multiple uniformity indicators monitored in engineering applications.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.