Answers are grounded in this paper and cite their sources.
Purpose of Review Superpulsed thulium fiber laser (sTFL) and Lumenis MOSES pulse-modulated holmium: yttrium-aluminum-garnet (Ho: YAG) represent contemporary standards for retrograde intrarenal surgery (RIRS), operating through distinct photothermal and pulse-shape modulation mechanisms. Previous meta-analyses comparing these modalities have yielded conflicting conclusions largely due to pooling heterogeneous, non-modulated Ho: YAG generations and diverse surgical procedures. This study aims to systematically review and meta-analyze existing evidence evaluating sTFL exclusively against MOSES Ho: YAG regarding stone-free rates, operative efficiency, and safety in adults undergoing RIRS for stones ≤ 20 mm. Recent Findings Of 1,290 records identified across five databases (PubMed, Scopus, Web of Science, ScienceDirect, and Europe PMC) through August 2026 (PROSPERO: CRD420261492557), 7 studies (3 randomized controlled trials and 4 comparative cohorts; 1,278 matched patients) met the inclusion criteria for the systematic review and meta-analysis. Meta-analysis showed that the sTFL cohort demonstrated a significantly superior absolute 0-mm stone-free rate compared to MOSES Ho: YAG (pooled RR 1.09, 95% CI 1.02–1.17, p = 0.014, I²=0.0%). However, clinically insignificant residual fragment (CIRF, ≤ 2–4 mm) rates were statistically equivalent between modalities both overall (pooled RR 1.06, 95% CI 0.93–1.21, I²=87.1%) and following the resolution of registry-driven heterogeneity (pooled RR 1.02, 95% CI 0.96–1.08, p = 0.59, I²=29.2%). Operative and lasing times were comparable between platforms. Both lasers exhibited equivalent overall complications (pooled RR 1.44, 95% CI 0.92–2.26) and severe adverse events (Clavien-Dindo ≥ III: RD 0.01, 95% CI − 0.00 to 0.02). Subgroup analyses revealed that elevated complication rates with sTFL were isolated to non-randomized, pure intrarenal cohorts (pooled RR 1.83, 95% CI 1.30–2.57) and follow-up ≥ 3 months (pooled RR 1.84, 95% CI 1.30–2.61), reflecting procedural confounders—such as ureteral access sheath underutilization—rather than inherent laser physics. Most studies were rated as having a high or serious risk of bias, primarily because of confounding and outcome measurement concerns. Leave-one-out sensitivity analyses supported the robustness of the findings. Summary This systematic review highlights that while sTFL achieves superior absolute stone clearance (0 mm), both sTFL and MOSES Ho: YAG yield equivalent CIRF rates, operative efficiency, and safety profiles under standardized operative conditions. Relying on institutional availability and enforcing strict intrarenal pressure management may be valuable strategies for guiding clinical laser application.
No takes yet. Share an insight, caveat, or question.
Qasem et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: