Key result
CTA guidance linked to ~21-point higher Bachmann's bundle pacing success vs conventional targeting.
Why the study?
Does CTA-guided anatomical targeting improve the feasibility, safety, procedural performance, and anatomical placement of Bachmann's bundle pacing compared to conventional electrogram- and fluoroscopy-guided implantation?
Cohort (n=77)
No
Does CTA-guided anatomical targeting improve the feasibility, safety, procedural performance, and anatomical placement of Bachmann's bundle pacing compared to conventional electrogram- and fluoroscopy-guided implantation?
CTA-guided anatomical targeting for Bachmann's bundle pacing is feasible and safe, significantly increasing implantation success rates and procedural efficiency compared to conventional fluoroscopic and electrogram guidance.
Answers are grounded in this paper and cite their sources.
May aid Bachmann's bundle pacing adoption; extends observational feasibility data but leaves open randomized validation.
Bachmann's bundle pacing (BBP) is an emerging physiological atrial pacing strategy, but implantation relies on fluoroscopic landmarks and iterative electrophysiological mapping. Whether patient-specific computed tomography angiography (CTA) can facilitate anatomical targeting of Bachmann's bundle has not been investigated. To evaluate the feasibility, safety, procedural performance, and anatomical impact of CTA-guided anatomical targeting for BBP. This retrospective, single-center, first-in-human study compared 49 consecutive patients undergoing CTA-guided BBP with 28 undergoing conventional electrogram- and fluoroscopy-guided implantation. Using predefined electrocardiographic criteria, successful BBP was achieved in 65 of 77 patients (84%) and was higher with CTA guidance (92% vs. 71%; P=0.024). CTA-guided implantation resulted in a different distribution of final lead positions, with more leads at the predefined B2-B3 target than with the conventional approach (76% vs. 42%; P=0.006; odds ratio 4.20; 95% CI, 1.52-11.60). CTA guidance reduced implantation time (median 2.0 [1.0-3.0] vs. 4.0 [3.0-7.0] minutes; P<0.001), fluoroscopy time (0.4 [0.2-0.6] vs. 1.6 [1.1-2.9] minutes; P<0.001), and lead deployment attempts (1.0 [1.0-2.0] vs. 2.0 [1.8-3.2]; P=0.001), and increased first-pass success (67% vs. 25%; P<0.001). In patients with successful BBP (n=65), BBP shortened P-wave duration in all cases (161±13 to 142±15 ms; relative reduction 11.6±4.4%; P<0.001), with similar reductions irrespective of implantation strategy. No acute lead-related complications occurred, and electrical performance remained stable during short-term follow-up. CTA-guided anatomical targeting for BBP is feasible and safe. Compared with conventional implantation, this anatomy-first strategy improves procedural efficiency, supporting anatomical guidance as a feasible approach to physiological atrial pacing.
No takes yet. Share an insight, caveat, or question.
Cano et al. (2026) conducted a cohort in Physiological atrial pacing via Bachmann's bundle pacing (n=77). CTA-guided anatomical targeting for Bachmann's bundle pacing vs. Conventional electrogram- and fluoroscopy-guided implantation was evaluated on Successful Bachmann's bundle pacing using predefined electrocardiographic criteria (p=0.024). CTA-guided anatomical targeting increased successful Bachmann's bundle pacing compared with conventional guidance and shortened implantation time.
Synapse has enriched 10 related papers. Consider them for comparative context: