Answers are grounded in this paper and cite their sources.
Digital anthropometry has become an increasingly important tool for obtaining body dimensions in clinical, ergonomic, and engineering applications. However, the validity of low-cost mobile LiDAR-based anthropometric systems remains insufficiently documented. The aim of this study was to evaluate the agreement of a mobile LiDAR-based anthropometric application and a professional three-dimensional body scanner with reference manual anthropometry. A total of 41 healthy volunteers underwent standardized manual anthropometric measurements, whole-body scanning using the TC² NX-16 scanner, and mobile scanning using the 3D Measure Up application. Agreement was evaluated using mean paired differences, intraclass correlation coefficients, and Bland–Altman analysis. Both digital systems showed good to excellent ICC values for most evaluated dimensions, but the magnitude and variability of the differences depended on the anthropometric parameter. Mean biases were generally smaller for linear dimensions, whereas the largest differences occurred among circumferential measurements. Representative Bland–Altman analyses showed wider limits of agreement for chest circumference than for body height. These findings suggest that mobile LiDAR-based anthropometry may complement professional scanning for selected linear dimensions under standardized conditions. However, circumferential measurements and measurements used for patient-specific decisions require additional verification.
No takes yet. Share an insight, caveat, or question.
Ondrejová et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: