Key result
ViV-TAVI yields ~14% 3-year mortality, with post-procedural gradients varying significantly across THV platforms.
Why the study?
Valve-in-valve TAVI is an established treatment for degenerated surgical aortic bioprostheses, but real-world outcome data across contemporary transcatheter heart valve platforms remain limited.
What are the procedural, haemodynamic, and mid-term clinical outcomes of ViV-TAVI across contemporary THV platforms in a national real-world cohort of patients with degenerated surgical aortic bioprostheses?
Cohort (n=258)
Yes
What are the procedural, haemodynamic, and mid-term clinical outcomes of ViV-TAVI across contemporary THV platforms in a national real-world cohort of patients with degenerated surgical aortic bioprostheses?
In a national Austrian registry, real-world ViV-TAVI across five contemporary THV platforms demonstrated favourable 30-day (4.7%) and 3-year (13.5%) mortality, though post-procedural transvalvular gradients varied significantly by device platform.
Answers are grounded in this paper and cite their sources.
Supports valve-in-valve TAVI feasibility in real-world registries; leaves open device-specific comparisons and long-term durability.
Background Valve‐in‐valve transcatheter aortic valve implantation (ViV‐TAVI) has become an established treatment for degenerated surgical aortic bioprostheses. However, real‐world outcome data using contemporary transcatheter heart valves (THV) remain limited. Aims To evaluate procedural, haemodynamic and mid‐term clinical outcomes of ViV‐TAVI across contemporary THV platforms in a national real‐world cohort. Methods This national multicentre registry evaluated all ViV‐TAVI procedures performed between 2018 and 2024 with five CE‐marked THV platforms in seven Austrian centres (~85% of national TAVI activity). Outcomes were assessed according to VARC‐3 criteria, and survival was evaluated using Kaplan–Meier estimates. Results Two hundred and fifty‐eight patients (48.4% female, mean age 78.2 ± 9.3 years) were included. Treated bioprostheses were predominantly stented (88.8%), most commonly 21 mm (34.5%) and 23 mm (32.2%). Implanted devices were Evolut (46.1%), Sapien (36.4%), Allegra (13.6%), Acurate (2.3%) and Navitor (1.6%). Patients were highly symptomatic (NYHA III–IV: 84.0%). Valve fracture and coronary protection were performed in 11.2% and 5.4%, respectively. Discharge echocardiography showed significant differences across device groups in mean gradients, ranging from 12.4 ± 5.5 mmHg (Allegra) to 21.4 ± 8.3 mmHg (Acurate; p < 0.001). VARC‐3 complications occurred in 19.0% overall ( p = 0.081 between groups); 30‐day mortality was 4.7%. At 3 years, cumulative mortality was 13.5%. Conclusions This multicentre registry demonstrated favourable procedural and mid‐term clinical outcomes, while differences in post‐procedural haemodynamics across THV platforms should be interpreted as exploratory because of the markedly unequal group sizes.
No takes yet. Share an insight, caveat, or question.
Will et al. (2026) conducted a cohort in Degenerated surgical aortic bioprostheses (n=258). Valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) across five contemporary THV platforms (Evolut, Sapien, Allegra, Acurate, Navitor) was evaluated on Cumulative mortality at 3 years, 30-day mortality, VARC-3 complications, and post-procedural haemodynamics (p=<0.001). ViV-TAVI resulted in 4.7% 30-day and 13.5% 3-year mortality, with discharge mean gradients varying across THV platforms from 12.4 to 21.4 mmHg.