Key result
Smartwatch irregular rhythm notifications are linked to ~4-fold higher odds of self-reported major cardiovascular events.
Why the study?
Smartwatch irregular rhythm notifications can identify atrial fibrillation, but their association with broader subsequent cardiovascular outcomes was unclear.
Is receipt of a smartwatch irregular rhythm notification associated with subsequent self-reported major adverse cardiovascular events in Apple Heart Study participants?
Cohort (n=293,944)
Is receipt of a smartwatch irregular rhythm notification associated with subsequent self-reported major adverse cardiovascular events in Apple Heart Study participants?
Answers are grounded in this paper and cite their sources.
Receipt of a smartwatch irregular rhythm notification was associated with a 4-fold higher adjusted odds of subsequent self-reported major adverse cardiovascular events, even in the absence of atrial fibrillation.
BACKGROUND: Smartwatch irregular rhythm notifications (IRNs) can identify atrial fibrillation. IRNs' association with broader cardiovascular outcomes is unclear. We evaluated whether receipt of an IRN in the AHS (Apple Heart Study) was associated with subsequent self-reported cardiovascular events. METHODS: We performed a post hoc analysis of the AHS, a prospective trial in the United States. Participants were enrolled via an iPhone app from 2017 to 2018; those who completed the end-of-study survey were included. The exposure was IRN receipt. Outcomes were self-reported new heart failure, myocardial infarction, stroke/transient ischemic attack, pulmonary embolism, and a composite of these events (major adverse cardiovascular events). Multivariable-adjusted logistic regression models included age, sex, heart failure, hypertension, diabetes, prior stroke/transient ischemic attack/systemic embolism, and vascular disease. RESULTS: Among 293 944 participants who completed follow-up, 929 (0.32% [95% CI, 0.30%-0.34%]) received an IRN. Participants with an IRN were older, more often male, and had a greater burden of cardiovascular risk factors. At the end-of-study survey, completed 5 to 14 months after enrollment, IRN receipt was associated with higher adjusted odds of self-reported heart failure (odds ratio, 5.43 [95% CI, 3.09-9.57]), stroke/transient ischemic attack (odds ratio, 3.51 [1.91-6.45]), pulmonary embolism (odds ratio, 4.43 [1.92-10.20]), and major adverse cardiovascular events (odds ratio, 4.01 [2.80-5.73]). Among participants with an IRN but without atrial fibrillation, IRN receipt remained associated with statistically significantly higher adjusted odds of self-reported heart failure and major adverse cardiovascular events. CONCLUSIONS: Receipt of a smartwatch IRN was associated with higher odds of subsequent self-reported cardiovascular events beyond atrial fibrillation. These findings suggest that IRNs may identify individuals at elevated short-term cardiovascular risk.
No takes yet. Share an insight, caveat, or question.
Pérez-Guerrero et al. (2026) conducted a cohort in Smartwatch irregular rhythm notification / Cardiovascular risk (n=293,944). Smartwatch irregular rhythm notification (IRN) receipt vs. No irregular rhythm notification receipt was evaluated on Self-reported major adverse cardiovascular events (composite of new heart failure, myocardial infarction, stroke/transient ischemic attack, and pulmonary embolism) (OR 4.01, 95% CI 2.80-5.73). Smartwatch irregular rhythm notification receipt was associated with higher adjusted odds of self-reported major cardiovascular events and heart failure.
Synapse has enriched 10 related papers. Consider them for comparative context: