Key result
Perceval Plus sutureless AVR achieves ~7-mmHg mean gradients without paravalvular leak, despite one recurrent VF.
Why the study?
Sutureless aortic valve replacement has emerged as an alternative to conventional sutured prostheses to reduce cardiopulmonary bypass and cross clamp times without compromising haemodynamic outcomes, and this report shares initial experience with the Perceval Plus bioprosthesis.
Case Report (n=2)
No
This initial two-patient case series demonstrates that Perceval Plus sutureless aortic valve replacement is technically feasible with favorable early hemodynamics, while highlighting the importance of vigilant postoperative rhythm monitoring following an episode of recurrent ventricular fibrillation.
Answers are grounded in this paper and cite their sources.
Requires arrhythmia monitoring after Perceval Plus; leaves open safety in larger prospective series.
Background: Sutureless aortic valve replacement (SU-AVR) has emerged as an effective alternative to conventional sutured prostheses reducing cardiopulmonary bypass and cross clamp times without compromising haemodynamic outcomes. Case Summary: We report our first two cases of isolated SU-AVR with the Perceval Plus bioprosthesis, in two women aged 69 and 70 years with severe symptomatic aortic stenosis. Post-deployment mean gradients were low (6 and 8 mmHg), with no paravalvular leak or coronary ostial obstruction on transoesophageal echocardiography. Case 2 recovered uneventfully and was discharged on postoperative day five. Case 1 developed recurrent ventricular fibrillation around 23 hours after surgery, with no electrolyte abnormality, valve dysfunction, or new regional wall motion abnormality identified; she responded well to defibrillation and antiarrhythmic therapy, and her subsequent recovery was uneventful. Conclusion: In this initial two-patient case series, sutureless aortic valve replacement was technically feasible, with favourable haemodynamic performance, though it also underscores the need for close postoperative rhythm monitoring, since arrhythmic events after sutureless implantation remain incompletely characterised in the literature.
No takes yet. Share an insight, caveat, or question.
Joshi et al. (2026) conducted a case report in Severe symptomatic aortic stenosis (n=2). Perceval Plus sutureless aortic valve replacement was evaluated on Post-deployment mean transvalvular gradient and perioperative complications. Perceval Plus sutureless aortic valve replacement achieved low post-deployment mean gradients (6 and 8 mmHg) without paravalvular leak in two patients, though one developed recurrent ventricular fibrillation.