Key result
Wearable NIRS/PPG monitoring signals cardiogenic shock deterioration ~4 hours before clinical collapse.
Why the study?
Cardiogenic shock can progress rapidly while conventional macrohemodynamic vital signs remain stable. Continuous noninvasive microcirculatory monitoring is uncommon, though it could provide early signals of impending decompensation.
Does continuous noninvasive microcirculatory monitoring with a wearable near-infrared spectroscopy and photoplethysmography device detect early signals of impending hemodynamic decompensation in cardiogenic shock?
Case Report (n=1)
Does continuous noninvasive microcirculatory monitoring with a wearable near-infrared spectroscopy and photoplethysmography device detect early signals of impending hemodynamic decompensation in cardiogenic shock?
In this first-in-human case report, wearable noninvasive microcirculatory monitoring detected hemodynamic deterioration approximately 4 hours prior to clinical collapse in terminal cardiogenic shock and correlated strongly with invasive hemodynamic parameters.
Answers are grounded in this paper and cite their sources.
May enable preemptive intervention before vital sign deterioration; hypothesis-generating for wearable microcirculatory monitoring in cardiogenic shock.
BACKGROUND: Cardiogenic shock can progress rapidly, even when conventional macrohemodynamic vital signs remain stable. Continuous, noninvasive microcirculatory monitoring is uncommon but could provide early signals of impending decompensation. FIH/EARLY REPORTS SUMMARY: The authors report near-infrared spectroscopy and photoplethysmography monitoring with the investigational NIRSense Envello Core wearable device. The patient was a 66-year-old man with complex valvular disease and combined pre/post capillary pulmonary hypertension, who rapidly deteriorated and died despite intensive care unit management. DISCUSSION: Chest-derived tissue oxygen saturation and perfusion index appeared to signal deterioration ∼4 hours before clinically recognized collapse, and correlated strongly with central venous pressure (r = -0.95; perfusion index) and systolic pulmonary artery pressure (r = 0.87; tissue oxygen saturation). NOVELTY: To our knowledge, this is the first continuous microcirculatory characterization of the transition to terminal cardiogenic shock using a wearable near-infrared spectroscopy and photoplethysmography device. TAKE-HOME MESSAGE: Noninvasive microcirculatory monitoring may detect hemodynamic collapse before conventional vital signs, identifying a potential window for earlier intervention.
No takes yet. Share an insight, caveat, or question.
Roumengous et al. (2026) conducted a case report in Cardiogenic shock (n=1). NIRSense Envello Core wearable near-infrared spectroscopy and photoplethysmography device was evaluated on Correlation of chest-derived tissue oxygen saturation and perfusion index with central venous pressure and systolic pulmonary artery pressure prior to hemodynamic collapse (r = -0.95 (perfusion index vs CVP); r = 0.87 (tissue oxygen saturation vs sPAP)). Wearable NIRS/PPG monitoring signaled cardiogenic shock deterioration ~4 hours before clinical collapse, correlating with CVP and sPAP.
Synapse has enriched 10 related papers. Consider them for comparative context: