Answers are grounded in this paper and cite their sources.
Methotrexate (MTX) is a widely used anticancer and immunosuppressive drug that requires precise monitoring to ensure therapeutic efficacy while minimizing adverse effects. In this study, a platinum electrode (PtE) modified with a polyurethane/multiwalled carbon nanotube (PU-MWCNT) nanocomposite film functionalized with gallic acid (GA) and microcrystalline cellulose (MCC) was developed for the selective, sensitive, and rapid electrochemical determination of MTX. The PU matrix was synthesized using GA, MCC, polyethylene glycol 1000 (PEG-1000), and an aliphatic diisocyanate, followed by the incorporation of MWCNTs at loadings of 1, 5, and 10 wt % relative to the mass of PU to enhance the electrochemical properties of the sensing interface. Among the prepared nanocomposites, PU-MWCNT1%/PtE exhibited the best electrochemical performance toward MTX. The developed sensor provided a broad linear range of 1–400 μM, with a detection limit of 0.086 μM and an approximately 3.39-fold increase in electroactive surface area compared with bare PtE. Under the optimized square-wave stripping voltammetry conditions, the analytical procedure consisted of a 45 s accumulation step followed by a 2 s equilibration period and an approximately 1.5 s voltammetric scan, resulting in a total measurement time of approximately 48.5 s. The sensor exhibited excellent within-electrode repeatability, with a relative standard deviation of 1.10% obtained from 25 consecutive measurements using the same modified electrode. The MTX response was maintained in the presence of potentially interfering species, including ascorbic acid, uric acid, glucose, and maltose, supporting the selectivity of the developed platform. Semiempirical quantum chemical calculations at the semiempirical PM6-level revealed a reduced highest occupied molecular orbital (HOMO)–lowest unoccupied molecular orbital (LUMO) energy gap (7.446 eV), an increased dipole moment (12.41 D), and a favorable interaction energy of −0.255 eV (−24.6 kJ mol–1) for the PU–MTX complex, supporting the formation of energetically favorable noncovalent interactions between PU and MTX. Based on the functional groups present in both structures, hydrogen bonding is suggested to contribute to the stabilization of the complex. Overall, the developed sensor platform represents a promising electrochemical approach for MTX determination, with potential for future applications in biological sample analysis and therapeutic drug monitoring.
No takes yet. Share an insight, caveat, or question.
Burç et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: