GHz ultrasonic interferometry is a few technique that can directly measure the VP and VS of iron (Fe) sample in a diamond anvil cell (DAC). In this study, we measured the VP and VS of hcp-Fe at high pressures and room temperature using the GHz interferometry method combined with a DAC and expanded the measurable pressure range of this method to 30 GPa. The sample density was measured using in-situ X-ray diffraction. The obtained VP and VS values were consistent with those reported in previous studies with differences of 2–8% for VP and 1–3% for VS. Furthermore, using the VP, VS, and density measured in this study, we obtained adiabatic bulk moduli of 276–301 GPa and the shear moduli of 106–135 GPa in the pressure range of 18–27 GPa.
No takes yet. Share an insight, caveat, or question.
Kurosaka et al. (2026) studied this question.