Key result
Emergency TEVAR via repeat iliac conduit successfully excludes ruptured thoracic aneurysm, enabling survival without spinal ischemia.
Why the study?
Endoleaks are the most common post-TEVAR complication and carry a high risk of rupture and mortality, while repeatedly used iliac conduit grafts may increase technical difficulty during subsequent procedures.
Case Report (n=1)
No
This case report demonstrates the feasibility of emergency endovascular management of a giant thoracic aortic aneurysm rupture due to a type IB endoleak by reusing a previously established iliac conduit.
Answers are grounded in this paper and cite their sources.
May increase future access difficulty with repeated iliac conduits in TEVAR; leaves open optimal strategies for repeated procedures.
Endoleaks are the most common post-TEVAR complication, clinically relevant due to the risk of persistent pressurization of the aneurysmal sac and hence rupture with mortality ranging from 44% to 100%. TEVAR requires delivery systems ranging from 18 Fr to 24 Fr, sometimes needing the creation of an iliac conduit using whether open or endovascular techniques. Repeatedly used iliac conduit grafts may lead to further local increased difficulty for their manipulation or use for future procedures. We present the case of a 64-year-old man presenting to the emergency department due to thoracic pain. He had two previous endovascular aortic aneurysm repairs (thoracic and abdominal). The contrast-enhanced Computed Tomographic scan revealed a type 1B endoleak in the descending aorta with an 11.5 cm aortic sac diameter enlargement which had a spontaneous rupture 4 days after admission, requiring an emergency management using a previous iliac conduit which had been used two times before leading to a hostile anatomic area, and hemothorax drainage. This case highlights the importance of close monitoring after any endovascular aortic repair due to the risk of stent-graft associated complications like endoleaks and their consequences, as well as the importance of the creation of a successful permanent vascular access through iliac conduits due to the possibility of further procedures.
No takes yet. Share an insight, caveat, or question.
Flores et al. (2026) conducted a case report in Giant thoracic aortic aneurysm sac rupture due to type IB endoleak (n=1). Emergency thoracic endovascular aortic repair (TEVAR) via a pre-established iliac conduit with subsequent iliofemoral bypass and right thoracotomy was evaluated on Survival and resolution of type IB endoleak without spinal cord ischemia. Emergency TEVAR using a third-time iliac conduit successfully excluded a ruptured 11.5 cm thoracic aneurysm from a type IB endoleak, achieving survival and discharge at 21 days without spinal ischemia.