Key result
Updated VARIPULSE software linked to ~2 more PFA applications per procedure without prolonging procedure time.
Why the study?
Does the updated VARIPULSE software (V8.1.1.944) with real-time tissue proximity indicator visualization and pulsed field tag coloring impact lesion delivery and procedural workflow compared to the previous software version (V8.1.0.325) in patients with atrial fibrillation undergoing pulmonary vein isolation?
Observational (n=146)
Does the updated VARIPULSE software (V8.1.1.944) with real-time tissue proximity indicator visualization and pulsed field tag coloring impact lesion delivery and procedural workflow compared to the previous software version (V8.1.0.325) in patients with atrial fibrillation undergoing pulmonary vein isolation?
Updated VARIPULSE software incorporating real-time tissue proximity indicators and enhanced tag coloring increases the number of pulsed field ablation applications delivered per procedure without prolonging procedure duration or increasing radiation exposure.
Answers are grounded in this paper and cite their sources.
Updated software linked to more PFA applications; hypothesis-generating for procedural changes and requires prospective outcome trials before adoption.
INTRODUCTION: The updated VARIPULSE™ software (V8.1.1.944) introduces a real-time tissue proximity indicator, enhanced VISITAG™ differentiation of complete versus incomplete applications, and grid-based color coding for lesion assessment during pulsed field ablation (PFA). Its impact on procedural workflow and lesion delivery remains insufficiently defined. METHODS AND RESULTS: We compared 55 pulmonary vein isolation procedures performed with the updated software and 91 procedures performed with the previous version (V8.1.0.325) in 146 consecutive patients with atrial fibrillation. The updated software was associated with a higher number of PFA applications per procedure (19.76 ± 4.10 vs. 17.74 ± 3.90; p < 0.001), with more applications across all pulmonary veins, without increases in fluoroscopy time, radiation dose, or procedure duration (54.06 ± 14.99 vs. 56.64 ± 17.23 min; p = 0.046). Procedure time decreased further after an initial learning curve of 30 cases. First-pass isolation of all pulmonary veins was achieved in 83.6% versus 78.0% of procedures (p = 0.41). CONCLUSION: These findings suggest modified, proximity-guided lesion delivery without a relevant workflow penalty.
No takes yet. Share an insight, caveat, or question.
Trajkovska et al. (2026) conducted an observational in Atrial fibrillation (n=146). Updated VARIPULSE software (V8.1.1.944) with real-time tissue proximity indicator and pulsed field tag coloring vs. Previous VARIPULSE software version (V8.1.0.325) was evaluated on Number of pulsed field ablation applications per procedure (p=< 0.001). Updated VARIPULSE software increased PFA applications per procedure without increasing procedure duration.