Key result
IVUS during EVAR linked to ~47% lower air kerma and less contrast without prolonging procedure time.
Why the study?
In EVAR for abdominal aortic aneurysm, contrast use and radiation exposure remain important clinical and occupational concerns. IVUS has been proposed as an adjunct to reduce contrast requirements and radiation dose, requiring evaluation of its impact on these parameters and early high-flow endoleaks.
Does adjunctive intravascular ultrasound (IVUS) reduce contrast volume and radiation exposure (dose-area product) in patients undergoing infrarenal endovascular aneurysm repair (EVAR)?
Cohort (n=95)
Does adjunctive intravascular ultrasound (IVUS) reduce contrast volume and radiation exposure (dose-area product) in patients undergoing infrarenal endovascular aneurysm repair (EVAR)?
Adjunctive IVUS during infrarenal EVAR is associated with reduced contrast volume and radiation exposure without increasing procedure or fluoroscopy time.
Answers are grounded in this paper and cite their sources.
IVUS may reduce contrast and radiation in EVAR; leaves open effects on endoleaks and need for randomized confirmation.
BACKGROUND: In endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm, contrast use and radiation exposure remain important clinical and occupational concerns. Intravascular ultrasound (IVUS) has been proposed as an adjunct that may reduce contrast requirements and radiation dose. AIMS: This study evaluated the impact of IVUS on contrast volume and radiation exposure-dose-area product (DAP) and air kerma (AK)-and explored its association with early high-flow endoleaks (Type I/III). METHODS: This retrospective observational study analyzed 95 consecutive infrarenal EVARs performed between August 2023 and September 2025. Primary outcomes were contrast volume and DAP; secondary outcomes were AK, fluoroscopy time, and procedure time. High-flow Type I/III endoleaks within 30 days were assessed as an exploratory outcome. Inverse probability weighting was applied to adjust for baseline imbalance. RESULTS: , p < 0.001), and AK (444.5 [341.2-635.4] mGy vs. 832.9 [466.6-1043.3] mGy, p < 0.001). Fluoroscopy and procedure times were similar. Early Type I/III endoleaks occurred in 2/68 versus 2/24 (p = 0.278). CONCLUSION: IVUS use during EVAR was associated with reduced contrast volume and radiation exposure without prolonging procedure or fluoroscopy time. No statistically significant difference in early high-flow endoleaks was observed, although the small number of events limits conclusions regarding safety. IVUS may serve as a valuable adjunct in EVAR for reducing contrast use and radiation exposure.
No takes yet. Share an insight, caveat, or question.
Ki et al. (2026) conducted a cohort in Abdominal aortic aneurysm undergoing infrarenal endovascular aneurysm repair (EVAR) (n=95). Intravascular ultrasound (IVUS) during EVAR vs. EVAR without intravascular ultrasound (IVUS) was evaluated on Contrast volume and dose-area product (DAP) (p=<0.001). IVUS use during EVAR reduced contrast volume, dose-area product, and air kerma without prolonging procedure time.
Synapse has enriched 10 related papers. Consider them for comparative context: