This work presents a model-based controller for a single-phase isolated inverter to supply AC auxiliary nonlinear loads in an electric vehicle (EV) application. The studied architecture consists of a two-stage configuration integrating an isolated DC-DC converter and a true-sine wave (TSW) inverter with an output LC filter. A proportional–integral–derivative (PID) regulator is designed to maintain a constant DC-link output voltage in the first stage. Furthermore, a proportional–resonant plus derivative (PR+D) control scheme is formulated in the second stage to guarantee a sinusoidal output voltage with low total harmonic distortion (THD) under nonlinear distorting load conditions. In particular, the PR+D controller is implemented considering a combined current formulation, where a single Hall-effect sensor is used to simultaneously measure both the output LC filter capacitor current and the load current. This approach offers two main benefits: first, it introduces essential damping due to the capacitor current, and, second, it enables the estimation of the inductor current amplitude for overcurrent protection purposes. Experimental results obtained at a rated power of 700 W are presented to validate the performance of the proposed control scheme.