Phantom study reveals turbulence-driven pressure gradients in venous sinus stenosis, indicating potential link to pulsatile tinnitus.
Motivation: Pulsatile tinnitus is related to changes in venous sinus hemodynamics. However, non-invasive quantification of turbulence and resulting irreversible pressure loss remains scarce. Goal(s): To non-invasively measure turbulence-driven pressure gradients in venous sinus stenosis. Approach: Pressure gradients were measured in a patient-specific flow phantom of venous sinus stenosis using 4D Flow MRI with ICOSA6 encoding in combination with the virtual work-energy relative pressure method (vWERP-t) and validated against catheter-based manometry. Results: The inclusion of turbulent dissipation had distinct impact on estimated relative pressures. vWERP-t derived pressures agreed with reference manometry but results directly depended on resolution and flow rate. Impact: This work demonstrates the feasibility of measuring turbulence-driven pressure gradients in venous sinus flows non-invasively, laying the groundwork for future in-vivo studies to investigate the relationship between pulsatile tinnitus and venous sinus hemodynamics.
No takes yet. Share an insight, caveat, or question.
Schollenberger et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: