Answers are grounded in this paper and cite their sources.
This paper presents a resistor-based high-resolution temperature-to-digital converter with an energy-efficient incremental delta-sigma analog-to-digital converter (IADC), implemented by hybrid continuous-time and discrete-time circuits. To reduce the flicker noise, the chopper switches are incorporated in the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1ˢᵗ</tex> -integrator. To further mitigate the degradation caused by the chopper, a finite impulse response (FIR) digital-to-analog converters (DAC) is added in the feedback loop filter to create frequency notches and eliminate the aliasing of the out-of-band noise due to chopping frequency. The proposed circuit is implemented in 180-nm CMOS process and, and the overall circuit consumes <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">166μ W</tex> from a 1.8 V power supply. The measured temperature resolution is less than 7.7 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">m∘C(1σ)</tex> in 0.1 ms, which corresponds to a resolution figure of merit (FoM) of 0.984 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">pJ·∘C²</tex> .
No takes yet. Share an insight, caveat, or question.
Lee et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: