Key result
Larger metallic ASD devices are linked to reduced LA reservoir strain versus smaller or less-metallic alternatives.
Why the study?
While percutaneous ASD closure typically normalizes cardiac volume, metallic device implantation may compromise left atrial compliance and contractility depending on device size and design.
Does the size and design of percutaneous ASD closure devices affect left atrial function in patients undergoing ASD closure?
Observational (n=105)
No
Does the size and design of percutaneous ASD closure devices affect left atrial function in patients undergoing ASD closure?
Intermediate or large conventional metallic ASD closure devices are associated with long-term left atrial functional impairment compared to smaller or less-metallic devices.
Answers are grounded in this paper and cite their sources.
Larger metallic ASD devices may reduce LA reservoir strain; challenges consensus on uniform recovery and leaves open optimal device selection in trials.
Background Percutaneous closure is the gold standard for ostium secundum atrial septal defect (ASD). While cardiac volume normalization typically follows closure, metallic device implantation may compromise left atrial (LA) compliance and contractility. We hypothesized that larger and conventional metallic devices would negatively impact LA function despite improved volume status. Purpose The objective of this study was to evaluate the impact of different sizes and designs of percutaneous ASD closure devices on LA function. We aimed to determine whether larger and conventional metallic closure devices adversely affect LA compliance and contractility, despite achieving cardiac volume normalization, compared to smaller or less-metallic devices. Through this investigation, we seek to inform optimal device selection to preserve atrial function post-ASD closure. Methods This single-center retrospective study analyzed 105 consecutive ASD patients undergoing percutaneous closure. Left atrial function was assessed using two-dimensional speckle tracking echocardiography (TOMEC software) at baseline and one year post-procedure. LA reservoir strain, a marker of atrial contractility, was the primary outcome. Results The cohort (median age 56 years, IQR 41-68; 13% with atrial fibrillation) demonstrated a significant reduction in LA reservoir strain one year post-procedure among patients receiving intermediate or large conventional metallic devices (Amplatzer septal occluder, Figulla flex II ASD occluder). In contrast, LA reservoir strain remained stable in patients with small metallic or less-metallic devices (Gore Cardioform septal occluder). Conclusions This study reveals a clinically significant association between the size and design of metallic ASD closure devices and long-term LA functional impairment. Careful device selection, considering both defect size and device material, is crucial to mitigate adverse effects on atrial function. Further research should investigate the long-term clinical implications of this finding.
No takes yet. Share an insight, caveat, or question.
Hashimoto et al. (2025) conducted an observational in Ostium secundum atrial septal defect (ASD) (n=105). Intermediate or large conventional metallic devices vs. Small metallic or less-metallic devices was evaluated on Left atrial reservoir strain. Intermediate or large conventional metallic ASD closure devices significantly reduced left atrial reservoir strain at 1 year compared to smaller or less-metallic devices.
Synapse has enriched 10 related papers. Consider them for comparative context: