Key result
Pre-TAVR leaflet splitting improves transcatheter valve expansion up to ~33% in bicuspid bench models.
Why the study?
Transcatheter aortic valve replacement deployment in bicuspid aortic valve can result in deformed transcatheter heart valves due to incomplete and eccentric stent expansion, and adjunctive pre-TAVR leaflet modification may improve valve expansion and reduce complications.
Does pre-TAVR bicuspid aortic valve leaflet modification improve THV expansion and reduce eccentricity in ex vivo and simulated bicuspid aortic valve models?
Does pre-TAVR bicuspid aortic valve leaflet modification improve THV expansion and reduce eccentricity in ex vivo and simulated bicuspid aortic valve models?
In a preclinical proof-of-concept study, pre-TAVR bicuspid aortic valve leaflet modification improved transcatheter heart valve expansion and reduced eccentricity compared to unsplit native valves.
Answers are grounded in this paper and cite their sources.
Bench models support testing leaflet modification to optimize TAVR in bicuspid valves; hypothesis-generating and requires clinical validation.
BACKGROUND: Transcatheter aortic valve replacement (TAVR) deployment in bicuspid aortic valve (BAV) can result in deformed transcatheter heart valves (THVs) due to incomplete, irregular, and eccentric stent expansion. Adjunctive pre-TAVR leaflet modification (LM)/splitting techniques may potentially reduce the circumferential leaflet stress exerted by the BAV leaflets on the THV, reduce risk of immediate complications, and improve THV expansion. OBJECTIVES: The aim was to introduce a new paradigm of pre-TAVR BAV LM and a proof-of-concept for THV geometry improvement. METHODS: )x100%. RESULTS: Both the 4 ex vivo bench cases and the 5 computed tomography-based simulation models demonstrated improvement in expansion ratio (up to 33%) and eccentricity (up to 31%) of deployed SEV/BEV THVs with pre-TAVR BAV splitting compared to their deployment in native BAVs without LM. For the BEV deployment in a type 1 bench model, dual pre-TAVR splitting yielded >10% increase in THV area and ∼5% decrease in ovality compared to a single split. CONCLUSIONS: In this proof-of-concept study, pre-TAVR BAV LM presents a promising adjunctive technique to promote THV expansion and circularity.
No takes yet. Share an insight, caveat, or question.
Jilaihawi et al. (2026) studied Bicuspid aortic valve (BAV) undergoing transcatheter aortic valve replacement (TAVR) (n=9). Pre-TAVR bicuspid aortic valve leaflet modification (splitting) vs. Native bicuspid aortic valves without leaflet modification was evaluated on Transcatheter heart valve expansion ratio and eccentricity. Pre-TAVR bicuspid aortic valve leaflet splitting improved transcatheter heart valve expansion ratio by up to 33% and reduced eccentricity by up to 31% in bench and simulation models.
Synapse has enriched 10 related papers. Consider them for comparative context: