This work demonstrates the design of pick-up coils in a superconducting system, indicating their role in quench studies.
The ATLAS Barrel Toroid (BT) is a superconducting toroid made of 8 superconducting coils of 25 m length and 5 m width, providing the magnetic field for the muon spectrometer of the ATLAS detector, one of the experiments of the Large Hadron Collider, under construction at CERN. In addition to the BT the ATLAS magnetic structure forsees two End Cap Toroid (ECT) with the same 8 structure geometry of the BT, and a Central Solenoid (CS).B00 is a small coil built to verify the performances of the different cables used in the ATLAS magnets, while B0 is a full scale model, one third length of ATLAS barrel toroid eight coils. The B0 construction was decided to test the technical construction solutions and reproduce the behaviour of the final coils. To fulfil this aim the coil has been equipped with many sensors, among which the pick-up coil are very important for the study of the quench characteristics. In the frame of this collaboration one of the item of the INFN was to provide some diagnostic sensors, among which about 20 pick-up coil, for the quench propagation studies. In this paper the design and characteristics of the pick-up coil used in the B00 and B0 model coil are described, together with the calibration procedure. Some data measured during the magnet test are reported and discussed.