Key result
Laplace TTVR resolves torrential tricuspid regurgitation and improves walking distance by ~168 m.
Why the study?
Severe tricuspid regurgitation in patients with small right atrial or right ventricular dimensions presents a significant challenge for transcatheter tricuspid valve replacement.
Does transcatheter tricuspid valve replacement with the Laplace system resolve torrential tricuspid regurgitation and improve functional capacity in a patient with a small right atrium and multiple ICD leads?
Case Report (n=1)
No
Does transcatheter tricuspid valve replacement with the Laplace system resolve torrential tricuspid regurgitation and improve functional capacity in a patient with a small right atrium and multiple ICD leads?
This case report demonstrates the feasibility of the investigational Laplace TTVR system to successfully eliminate torrential tricuspid regurgitation and improve functional status in a patient with a small right atrium and multiple ICD leads that precluded the use of commercially available TTVR devices.
Answers are grounded in this paper and cite their sources.
Offers potential option for anatomy precluding commercial devices; leaves open safety, durability, and generalizability in prospective studies.
BACKGROUND: Severe tricuspid regurgitation (TR) in patients with small right atrial (RA) or right ventricular dimensions poses a significant challenge for transcatheter tricuspid valve replacement (TTVR). CASE SUMMARY: A 39-year-old woman with prior coronary artery bypass grafting, mitral valve replacement, and LMNA cardiomyopathy with a dual-chamber implantable cardioverter-defibrillator presented with torrential TR. She was deemed to be a poor surgical candidate, and TTVR with the EVOQUE system was aborted due to insufficient RA height. She underwent TTVR with the Laplace system. Imaging confirmed resolution of TR, and the patient had notable and sustained improvements in her functional capacity and quality of life at 6-month follow-up. DISCUSSION: This case demonstrates the feasibility of the Laplace TTVR system for treating severe TR in a patient with small RA/right ventricular size that precluded the use of currently available commercial TTVR devices. TAKE-HOME MESSAGE: Novel TTVR systems may provide additional options for treating TR in patients with challenging anatomy.
No takes yet. Share an insight, caveat, or question.
Bauer et al. (2026) conducted a case report in Torrential tricuspid regurgitation with small right atrium and multiple cardiac implantable electronic device leads (n=1). Laplace transcatheter tricuspid valve replacement (TTVR) system was evaluated on Tricuspid regurgitation resolution and functional status at 6-month follow-up. Laplace transcatheter tricuspid valve replacement resolved torrential tricuspid regurgitation and improved walking distance from 302 m to 470 m and quality of life from 42.2 to 93.3 at 6 months.
Synapse has enriched 10 related papers. Consider them for comparative context: