Key result
Higher Uni/Bi ratio at index AF ablation predicts greater bipolar LVZ expansion at redo ablation.
Why the study?
Atrial substrate progression is common in AF patients, and unipolar voltage mapping more comprehensively characterizes the atrial substrate than bipolar mapping.
Does unipolar voltage mapping predict atrial substrate progression in patients with recurrent atrial fibrillation?
Observational (n=50)
No
Does unipolar voltage mapping predict atrial substrate progression in patients with recurrent atrial fibrillation?
A higher ratio of unipolar to bipolar low-voltage zone area during index ablation predicts greater atrial substrate progression in patients with recurrent atrial fibrillation.
Answers are grounded in this paper and cite their sources.
May aid AF substrate progression risk stratification; extends voltage mapping predictors but remains hypothesis-generating pending validation.
BACKGROUND: Atrial substrate progression is common among patients with atrial fibrillation (AF). Unipolar voltage mapping more comprehensively characterizes the atrial substrate compared with bipolar mapping. OBJECTIVE: This study aimed to characterize atrial substrate progression in patients with recurrent AF using unipolar mapping after pulmonary vein isolation. METHODS: In this single-center retrospective study, consecutive AF patients undergoing index and redo ablations were enrolled. Electroanatomic maps from both ablations were compared and assessed by unipolar and bipolar voltage. Low-voltage zone (LVZ) was defined as bipolar voltage <0.5 mV or unipolar voltage <1.6 mV. Patients were categorized into progression (n = 35) and nonprogression (n = 15) groups. RESULTS: , p = 0.007) and LVZ burden (0.20 vs. 0.14, p = 0.002). The progression group showed a higher LVZ burden (unipolar: 0.27 vs. 0.12, p = 0.007; bipolar: 0.16 vs. 0.09, p = 0.019) and a greater ratio of total unipolar to bipolar LVZ area (Uni/Bi) (1.75 vs. 1.34, p = 0.042) during index ablation compared with the nonprogression group. Linear regression revealed a positive correlation between index-ablation Uni/Bi ratio and the degree of Bi-LVZ area expansion at redo ablation (β = 7.20, p < 0.001). CONCLUSION: Uni-LVZ characterizes the atrial substrate progression, with the higher Uni/Bi ratio during index ablation indicates greater Bi-LVZ expansion at redo ablation.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2026) conducted an observational in Atrial fibrillation (AF) (n=50). Higher unipolar to bipolar low-voltage zone area ratio (Uni/Bi) vs. Lower Uni/Bi ratio was evaluated on Degree of bipolar low-voltage zone (Bi-LVZ) area expansion at redo ablation (β = 7.20, p=<0.001). A higher ratio of total unipolar to bipolar low-voltage zone area during index ablation was positively correlated with greater bipolar low-voltage zone expansion at redo ablation.