Key result
TAPSE×PAAT matches TAPSE/PASP in evaluating functional capacity and RV-PA coupling in advanced heart failure.
Why the study?
Does the echocardiographic index TAPSE×PAAT correlate with functional capacity (peak VO2) comparably to TAPSE/PASP in patients with advanced heart failure?
Observational (n=194)
No
Does the echocardiographic index TAPSE×PAAT correlate with functional capacity (peak VO2) comparably to TAPSE/PASP in patients with advanced heart failure?
TAPSE×PAAT is a valid, TR-independent echocardiographic alternative to TAPSE/PASP for assessing RV-PA coupling and functional capacity in advanced heart failure.
Answers are grounded in this paper and cite their sources.
Supports TAPSE×PAAT as complementary RV-PA coupling surrogate in advanced HF when PASP estimation limited; extends noninvasive options pending prospective validation.
Background Right ventricular–pulmonary arterial (RV–PA) coupling plays a central role in determining functional capacity in advanced heart failure (HF). Although the TAPSE/PASP ratio is widely used as a noninvasive surrogate of RV–PA coupling, its applicability may be limited by the availability and quality of tricuspid regurgitation Doppler signals. Pulmonary artery acceleration time (PAAT) is a TR‐independent marker of pulmonary vascular load, and the composite index TAPSE×PAAT has emerged as a potential alternative. Methods This retrospective single‐center study included 194 patients with advanced HF who underwent comprehensive transthoracic echocardiography, cardiopulmonary exercise testing, and right heart catheterization. Patients were stratified according to TAPSE×PAAT tertiles. Associations between RV–PA coupling indices (TAPSE/PASP and TAPSE×PAAT) and functional capacity, assessed by peak oxygen uptake (peak VO 2 ), were evaluated using multivariable regression models after variable selection with LASSO. Model performance was compared using adjusted R 2 , AIC, and RMSE. Results Higher TAPSE×PAAT values were associated with progressively better exercise performance. Peak VO 2 increased stepwise across TAPSE×PAAT tertiles (11.3 ± 3.7 vs. 13.4 ± 3.7 vs. 15.3 ± 3.9 mL/kg/min, p < 0.001). In multivariable analyses, both TAPSE/PASP and TAPSE×PAAT remained independently associated with peak VO 2 . The TAPSE/PASP model demonstrated slightly better global fit statistics (adjusted R 2 = 0.511 vs. 0.500; AIC = 980.8 vs. 985.0; RMSE = 2.66 vs. 2.69), whereas TAPSE×PAAT showed consistent statistical significance across models. Agreement between predicted peak VO 2 values derived from both indices was high. Conclusion In advanced HF, TAPSE×PAAT, and TAPSE/PASP showed comparable relationships with functional capacity, supporting TAPSE×PAAT as a complementary echocardiographic surrogate of RV–PA coupling, particularly in clinical settings where PASP estimation is limited.
No takes yet. Share an insight, caveat, or question.
Karaçam et al. (2026) conducted an observational in advanced heart failure (n=194). TAPSE×PAAT vs. TAPSE/PASP was evaluated on functional capacity assessed by peak oxygen uptake (peak VO2) (p=<0.001). Higher TAPSE×PAAT values were associated with progressively better exercise capacity across tertiles, demonstrating comparable performance to TAPSE/PASP.