Key result
Bicuspid anatomy linked to ~270% higher adverse event risk after TAVI versus tricuspid valves.
Why the study?
Higher eccentricity indicating prosthesis deformation is often detected in bicuspid valves, which might lead to valvular and perivalvular thrombosis and worse outcomes despite preserved echocardiographic performance.
Does transcatheter aortic valve implantation in bicuspid aortic valve stenosis compared to tricuspid aortic valve stenosis result in increased prosthesis deformation and worse outcomes?
Observational (n=100)
Does transcatheter aortic valve implantation in bicuspid aortic valve stenosis compared to tricuspid aortic valve stenosis result in increased prosthesis deformation and worse outcomes?
TAVI in bicuspid aortic valves is associated with greater prosthesis eccentricity, higher rates of thrombosis, and increased risk of adverse events compared to tricuspid valves, despite similar echocardiographic performance.
Answers are grounded in this paper and cite their sources.
May warrant enhanced post-TAVI thrombosis surveillance in bicuspid valves; leaves open causal links and need for prospective confirmation.
OBJECTIVES: We sought to assess whether post-implant transcatheter aortic valve prosthesis multidetector computed characteristics differ between patients with native tricuspid and bicuspid aortic valve stenosis, as well as the effect on valve performance and clinical implications. METHODS: We analysed 100 consecutive post-implant multidetector computed tomography scans to assess self-expandable prosthesis non-uniform expansion at 6 pre-specified valvular levels, and other specific parameters, including valvular and perivalvular thrombosis at 6 months follow-up. Echocardiographic prosthesis performance and clinical outcome were also evaluated. RESULTS: Mean eccentricity was significantly higher in the bicuspid group (0.43 (0.09) vs 0.37 (0.08), P = 0.005, bicuspid vs tricuspid); valvular and perivalvular thrombosis were also significantly more frequent in the bicuspid than in the tricuspid group (81% vs 36.9%, P = 0.031); there was no significant difference in terms of mean prosthetic gradient at follow-up between (7.31 (5.53 mmHg) vs 7.09 (3.05 mmHg), P = 0.825); EOAi (indexed effective orifice area) was also similar between bicuspid and tricuspid (1.08 (0.12 cm2) vs 1.03 (0.13 cm2), P = 0.101), with no significant changes compared to discharge. However, the bicuspid valve was associated with a significantly higher risk of adverse events (HR: 3.72, 95% CI: 1.07-13.4, P = 0.027). CONCLUSIONS: Higher level of eccentricity, which indicates prosthesis deformation, is often detected in bicuspid valves. Although echocardiographic performance was not affected, this might have led to an increased incidence of thrombosis at valvular and perivalvular levels and worse outcomes.
No takes yet. Share an insight, caveat, or question.
Moscarelli et al. (2024) conducted an observational in aortic valve stenosis (n=100). Bicuspid aortic valve vs. Tricuspid aortic valve was evaluated on adverse events (HR 3.72, 95% CI 1.07-13.4, p=0.027). Bicuspid aortic valves were associated with higher mean eccentricity, more frequent thrombosis, and a higher risk of adverse events than tricuspid valves.